INSTALLATION
SYSTEM GUIDELINES
Prints Specific Per Installation
Often times, installation prints are custom drawn for each
site. You should check those prints for information that
is specific to your installation. Any deviations from those
prints made during or after installation should be recorded
for further reference.
Cable Assemblies
Most electrical interconnections between the DynaFlow
controller and other system components are made through
cable assemblies.
Equipment Locations
With the exception of the following restrictions, the
installation of the Transducers or Transducer Panel, the
Remote Operators Station and Regulator/Flow meter
assemblies are application and site dependant. Specific
instructions for location and mounting of these assemblies
are covered on the site installation drawings.
Equipment Grounding
1. The maximum recommended distance from the Control
Panel to each flow meter is 100-ft. as determined by the
maximum standard available length of the fiber-optic
cable assemblies or intrinsic electrical cable assemblies.
2. The maximum recommended length of air pilot tubing
between the electrical-to-pneumatic (E/P) transducer
and the material regulator is largely determined by the
application. In general, the pilot lines should be kept as
short as possible to achieve the best fluid flow response
and regulation. See "Pilot Signal Guidelines" chart in
this section.
3. The maximum distance between the optional LBAL5001-
XX Pneumatic Interface Panel to the Control Console
is 40-ft., as determined by the interconnecting electrical
cable assembly.
4. The maximum recommended 1/4-inch OD hose length
from the LBAL5003, Remote Operator Panel, and the
LBAL5001, Pneumatic Interface Panel, is 20-ft., however
this can be longer depending on the application. The
maximum distance between the A12182 interface panel
and the A12233 console is 50-ft.
5. The maximum recommended length for the E/P
transducer electrical control cable is 95 ft. However, in
some cases 175-ft. has been used. Generally, if a GUN
number (not atomizers) controls a complete zone of 6
or more atomizers, do not exceed 95-ft. of cable.
Consult Ransburg if longer distances than those shown
above are desired.
CAUTION
!
NOTE
Any unused conduit holes must be blanked off
to prevent solid objects from entering the interior of
the enclosure.
The control panel should be grounded in
accordance with national and local electrical codes.
The protective ground conductor must be
terminated directly to the protective conductor ground
terminal located inside the Control Enclosure which is
marked with symbol -
LN-9400-00-R11 (08/2018)
17 / 96
www.carlisleft.com
INSTALLATION
Содержание Ransburg DynaFlow 77376
Страница 13: ...Figure 1 Block Diagram Return To Contents LN 9400 00 R11 08 2018 13 96 www carlisleft com INTRODUCTION...
Страница 90: ...Fluid Panel Sheet 1 Return To Contents LN 9400 00 R11 08 2018 90 96 www carlisleft com APPENDIX...
Страница 91: ...Fluid Panel Sheet 2 Return To Contents LN 9400 00 R11 08 2018 91 96 www carlisleft com APPENDIX...
Страница 92: ...Fluid Panel Sheet 3 Return To Contents LN 9400 00 R11 08 2018 92 96 www carlisleft com APPENDIX...