 1.   Connect your high-pressure fluid hose to the gun fluid 

inlet and tighten securely.

2.  

Connect your air hose to the gun air connection and 
tighten securely.

3.   Slowly increase air to the pump to obtain a fluid pressure 

at the gun’s lower end of the pressure range. A typical 
starting fluid pressure is 17 bar [250 psi]. Actual starting 
pressure points may be higher or lower than 17 bar [250 
psi] and depend on the setup including the type of pump 
used, the type of material sprayed, and the spray gun 
itself.

4.   Using the control knob on the air regulator, set the air 

pressure at zero.

5.   To test the spraying pattern, spray a piece of wood or 

cardboard with a fast pass about one foot away from the 
surface. The results of the test will allow you to 
determine the uniformity of the particle size and 
spraying pattern.

6.  

If the spraying pattern develops tails or is not uniform, 
gradually increase the air pressure as necessary to 
develop a uniform spraying pattern. 1 bar [14 psi] is the 
maximum inlet air pressure for HVLP (1 bar [15 psi] 
max. for HVLP twist tip cap), or use 1.4-2.8 bar [20-40 
psi] inlet air pressure for LVMP. The HVLP flat tip and 
twist tip air caps consume 230 L/m [8.3 SCFM] air at 
their respective maximum inlet air pressures. The 
LVMP flat tip and twist tip air caps consume 368 L/m 
[13 SCFM]

 at 2.1 bar [30 psi] inlet air pressure. The air 

is used to assist the atomization of the coating.

7.   If the quality of spray is acceptable, begin spraying. If 

the spraying rate is too slow to keep up with the 
production line speed, or if the quantity of material 
sprayed is inadequate for acceptable coverage, gradually 
increase the fluid pressure in 3.4 bar [50 psi] increments 
using the fluid regulator control knob. However, note 
that as the fluid pressure increases, more air is needed to 
eliminate the tails.

Consistency in spraying can be increased across spray gun 
operators and similar spraying jobs by developing pressure 
standardization charts. Repeat step 6 until the required 
material coverage and spraying speed are achieved. If the 
maximum fluid pressure is reached before the required 
material coverage and spraying speed are achieved, you may 
need to switch to a larger fluid tip.

TYPICAL HOOK-UP

Fan pattern adjustment: turn knob counterclockwise to 
decrease pattern; clockwise to increase pattern (Fig. 2). 

SPRAY GUN SET-UP

Figure 2

Fan  

Adjustment  

Control Knob

When using the 

twist tip air cap, the 

primary purpose of 

the fan pattern 

adjustment knob is 

to eliminate tails in 

the spray pattern.

FLUID TIP SELECTION

Factors to consider in selecting a fluid tip for an air-assist 
airless spray gun include (1) the size of the parts being 
sprayed; (2) the production line speed; (3) the material 
flow rate and film thickness; (4) the viscosity of the 
material applied; (5) the type of material applied; and (6) 

the quality of atomization of the coating required.  
The selection of a fluid tip necessary to perform a 
specific spraying job is best determined through a 
combination of experimentation and expert advice from 
your material and equipment suppliers.

FLUID HOSES

Air-assist airless spray guns operate at fluid pressures 
higher than operating pressures of air spray guns. As a 
result, when operating an air-assist airless spray gun, it is 

critical to select the appropriate fluid hose that is rated for 
the pressure range at which the airless gun is operated.

NOTE

For HVLP spray, fan adjustment feature requires 1 bar [14 

psi] max. of air inlet pressure (1 bar [15 psi] max. for HVLP 

twist tip.) For LVMP spray, fan adjustment requires 

approximately 1.4-2.8 bar [20-40 psi] of air inlet pressure. 

Higher fluid pressure requires higher air inlet pressures to 

accommodate pattern adjustment.

NOTE

Before proceeding, make sure trigger lock is engaged.

NOTE

Do not hang gun by trigger. This will cause needle damage 

or malfunction.

Pump

Regulator

Regulator

Air

Air

Air

Fluid

Fluid Filter

Oil and Water 

Extractor

Figure 1

Air 

In

Gun

EN

77-2922-R12  (4/2021)

4 / 16

www.carlisleft.com

Содержание Binks AA4400M

Страница 1: ...bide tip by the typical 110 262 bar 1 600 3 800 psi fluid pressure with capabilities up to 303 bar 4 400 psi As a result of the pre atomizing the final shaping air supplied by the air cap produces an...

Страница 2: ...on Level II 2 G X Notified body details and role Element Materials Technology WN8 9PN UK Lodging of Technical file 14 Apr 16 Signed for and on behalf of Carlisle Fluid Technologies Machinery Directive...

Страница 3: ...Relieve all pressure before servicing Spray from the spray gun hose leaks or ruptured components can inject fluid into your body and cause extremely serious injury PRESSURE RELIEF PROCEDURE Always fol...

Страница 4: ...similar spraying jobs by developing pressure standardization charts Repeat step 6 until the required material coverage and spraying speed are achieved If the maximum fluid pressure is reached before t...

Страница 5: ...et Air Pressure 1 bar 14 psi Gun Body Forged Aluminum Alloy Fluid Path Stainless Steel and Tungsten Carbide PEEK PROBLEM CAUSE ACTION Fluid leaking from through the seal Worn seal or needle shaft Loos...

Страница 6: ...ch cleaning The points that need lubrication during the maintenance of air assist airless spray guns include the fluid needle packing and trigger pivot point Gun lube is used to lubricate the fluid ne...

Страница 7: ...fluid nozzle and gasket Torque fluid nozzle from 12 15 N m 9 11 ft lbs See fig 5 5 Replace the air cap along with spray tip See fig 4 REPLACING THE FLUID NEEDLE ASSEMBLY 1 Remove the trigger by removi...

Страница 8: ...ht resistance due to seal e Rear seal must look clean and in position in the bore See fig 18 f If any of the above cannot be rectified replace the air valve See Replacing Air Valve p8 8 Replace spring...

Страница 9: ...must fit in service tool form See fig 32 8 Push rear seal firmly into hole up to shoulder using Service tool See figs 33 34 9 Insert new spring ensuring the end with the plastic bearing pad goes in f...

Страница 10: ...ly hand tightened See fig 39 5 Slip on the plastic tip guard onto the air cap in proper orientation See fig 40 6 Place round bar screwdriver between open sections of the plastic guard and push down wi...

Страница 11: ...1 29 30 31 TWIST TIP PARTS FLAT TIP PARTS 12 15 N m 9 11 FT LBS 12 15 N m 9 11 FT LBS 24 30 N m 18 22 FT LBS 12 15 N m 9 11 FT LBS 24 30 N m 18 22 FT LBS 24 30 N m 18 22 FT LBS 19 22 N m 14 16 FT LBS...

Страница 12: ...4 1836 30 DISC FILTER HOUSING 1 31 DISC FILTER RETAINING NUT 1 ITEM PART NO NO DESCRIPTION QTY PARTS LIST When ordering please specify Part No Not all Part Nos are available for purchasing Refer to pa...

Страница 13: ...013 10 0 18 9 613 75 TWIST TIP 013 12 0 18 9 713 75 TWIST TIP 013 14 0 18 9 215 75 TWIST TIP 015 4 0 24 9 315 75 TWIST TIP 015 6 0 24 9 415 75 TWIST TIP 015 8 0 24 9 515 75 TWIST TIP 015 10 0 24 9 61...

Страница 14: ...NOTES EN 77 2922 R12 4 2021 14 16 www carlisleft com...

Страница 15: ...NOTES EN 77 2922 R12 4 2021 15 16 www carlisleft com...

Страница 16: ...notice BGK Binks DeVilbiss Hosco MS and Ransburg are all registered trademarks of Carlisle Fluid Technologies Inc 2021 Carlisle Fluid Technologies Inc All rights reserved For technical assistance or t...

Отзывы: