4
. Lamp Installation a
nd Replacement Instructions
Danger!!
Turn power off at source before removing end covers and servicing lamps. A fatal electrical shock
could possibly result.
Precautions
for Handling Quartz Infrared Lamps
Do not handle infrared lamps with bare hands.
Remove any contaminations with alcohol and a
clean, soft cloth. Contaminations on quartz tubes cause the quartz to overheat, which may lead to
premature lamp failure.
Caution!!
If lamps are replaced, with lamps having metal ends, metal ends must be removed to permit
proper assembly and prevent the possibility of arcing or shorting.
Lamp Installation
/
Replacement Procedure
1. Make sure main system circuit breaker is OFF.
2. Rotate heater so lamps are horizontal.
3. Remove end covers to gain access to lamp leads.
4. Disconnect wire from the ceramic terminal block and remove lamp that is being replaced.
5. Carefully slide the lamp through the lamp support.
6. Remove electrical insulation sleeves from the old lamp on both lamp leads and install them on the
new lamp leads. Push the sleeve to the ceramic end of the lamp (see drawing below).
7. Secure the lamp lead to the power wire coming into the heater at the ceramic terminal block.
8. Install end covers.
NOTE: If lamp leads are too tight, damage to lamp may result.
Make sure lamp sleeving
is pushed all the way into
ceramic end of lamp
Lamp Support
(outer reflector)
End Cover
Ceramic terminal
in heater head
Ensure all bare wire is
contained up to terminal
(trim lead if necessary)
Heater Power Co
Содержание BGK AutoCure 6000-2216
Страница 1: ...AutoCure 6000 2216 Overhead Heater Assembly and Operating Manual ...
Страница 22: ......
Страница 23: ......
Страница 37: ......
Страница 38: ......
Страница 41: ...A DETAIL J SCALE0 40 1 REMOVET1 11SBOLTAFTERINSTAI I ATION ...
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ...AUTOCURE MODEL NUMBER AC6 2216 480 SP ...
Страница 48: ......
Страница 49: ......