Flexicode
Signal Diagrams
11.19
Operating Manual
95
10 Signal Diagrams
10.1 Continuous Mode
NOTICE!
The line 'data receipt' indicates when the direct print module
receives data.
Number of layouts per print order: 1
Data memory: standard
Ribbon save: On
Trigger input print start: increasing slope
In 'dispenser mode: dynamic' the layout distance onto the material is
not determined by the layout length but by the time between start
impulse and print start input.
Because of the fact that the setting 'data memory: standard' the next
print order is generated after the previous one is finished and a print
order is only finished after the feed of the complete layout, the
smallest possible time between two start impulses depends also from
the layout length.
In case the printable data is only at the beginning of the layout and the
rest of the layout is empty, then the time of start impulse by minimising
the layout length (not for 'data memory: extended') can be decreased.
As soon as the generation of a layout is finished, a new one is send to
the direct print module. The time of receipt for the first layout is
normally shorter because at this time the direct print module has no
further action. At receipt of the following layout, the time of receipt is
longer because the direct print module receives data and prints at the
same time.
Dispenser mode:
Dynamic
Layout
Data receipt
Содержание FLEXICODE 53
Страница 1: ...FLEXICODE Operating Manual ...
Страница 8: ...Introduction Flexicode 8 Operating Manual 11 19 ...
Страница 14: ...Machine Overview Flexicode 14 Operating Manual 11 19 ...
Страница 18: ...Operating Conditions Flexicode 18 Operating Manual 11 19 ...
Страница 40: ...Installation and Initial Operation Flexicode 40 Operating Manual 11 19 ...
Страница 44: ...Operation Panel Flexicode 44 Operating Manual 11 19 ...
Страница 94: ...Maintenance and Cleaning Flexicode 94 Operating Manual 11 19 ...
Страница 100: ...Signal Diagrams Flexicode 100 Operating Manual 11 19 ...
Страница 114: ...Additional Information Flexicode 114 Operating Manual 11 19 ...
Страница 116: ...Environmentally Friendly Disposal Flexicode 116 Operating Manual 11 19 ...