30 Chapter 5  Acquiring Cephalometric Images

Launching the X-ray

To launch the X-ray, follow these steps:

1

Leave the X-ray room and close the door. You must keep visual contact with the patient during 
acquisition.

Figure 6

Frontal AP

Figure 7

Frontal PA

Important:  If you have a problem that requires you to stop the 
acquisition, release the exposure button of the remote control or 
press the red emergency stop button.

Содержание CS 8100SC Access

Страница 1: ...CS 8100SC Family User Guide Including CS 8100SC CS 8100SC Access...

Страница 2: ...for growth and maturity assessment The CS 8100SC Family includes CS 8100SC The complete panoramic and cephalometric modality CS 8100SC Access The panoramic modality without the 2D radiological exam fe...

Страница 3: ...c Acquisition Interface Overview 12 Cephalometric Program Pane 13 Cephalometric Patient Pane 14 Cephalometric Parameter Pane 15 Chapter 4 Getting Started Switching on the Unit 17 Increasing the operat...

Страница 4: ...paring the Unit and Setting the Acquisition Parameters 36 Preparing and Positioning the Adult and Pediatric Patient 37 Launching the X ray 39 X ray Dose Emission Information 40 Acquiring a Carpus Imag...

Страница 5: ...icate potential risk to personnel or equipment WARNING Warns you to avoid injury to yourself or others by following the safety instructions precisely CAUTION Alerts you to a condition that might cause...

Страница 6: ...2 Chapter 1 Conventions in This Guide...

Страница 7: ...ogical exam feature and the cephalometric modality without the 26 x 24 FoV This document refers to both models as CS 8100SC unless otherwise specified Mobile Components Figure 1 illustrates the Up and...

Страница 8: ...ator 3 Emergency stop knob 13 Secondary collimator 4 ON OFF button 14 Nasion support 5 Cephalostat arm 15 Head clamps and ear cones 6 Cephalostat head 16 Cephalometric digital sensor 7 X ray source as...

Страница 9: ...CS 8100SC Family User Guide SM987 _Ed 01 5 Digital Sensor Locations Figure 3 illustrates the locations of digital sensors of the unit Figure 3 CS 8100SC Unit Digital Sensor Locations...

Страница 10: ...re used when positioning a patient They are delivered with the CS 8100SC Table 1 Panoramic Positioning Accessories Accessory Description Panoramic chin rest Sinus chin rest TMJ nose rest Standard bite...

Страница 11: ...CS 8100SC Family User Guide SM987 _Ed 01 7 Table 2 Cephalometric Positioning Accessories Accessory Description Single use sheaths for ear cones Carpus panel optional Frankfort positioning indicator...

Страница 12: ...en the unit is not in use places the rotative arm in a parallel position to the unit head leaving more free space around the unit To do so press and hold both buttons until the Ready Indicator LED swi...

Страница 13: ...to launch a radiological image acquisition via the exposure button from outside the X ray room You must press and hold the exposure button until the end of acquisition Premature release of the exposur...

Страница 14: ...10 Chapter 2 CS 8100SC Overview...

Страница 15: ...essary you MUST update your computer system configuration The unit MUST be connected to the computer via a point to point Ethernet link and not via a LAN General Software Overview The CS 8100SC operat...

Страница 16: ...5 Generator Cooling indicator Indicates the automatic cooling time mm ss required before the next acquisition 6 X ray dose Displays the dose that will be emitted before each acquisition 7 Reset butto...

Страница 17: ...Click for an oblique exam Click for a frontal AP Anterior Posterior exam Click for a submento vertex exam Click for a frontal PA Posterior Anterior exam Click for a carpus exam 2 FoV options Select fo...

Страница 18: ...meters must be based on the age and morphology of the patient Figure 8 Cephalometric Patient Pane Note A selected patient mode sets the kV and mA Patient type parameters Pediatric mode Click if the pa...

Страница 19: ...er setting is not adapted to your patient type you can manually adapt the parameter setting to the patient type and save this setting as the default setting To save a parameter setting for a specific...

Страница 20: ...16 Chapter 3 Imaging Software Overview...

Страница 21: ...now proceed to start the Acquisition interface from the imaging software Increasing the operating life of the X ray tube To increase the operating life of the X ray tube follow these steps 1 In the P...

Страница 22: ...desktop double click Carestream s Dental Imaging Software or CS Imaging Software to open the imaging software The Windows Security Alert dialog box displays Select Private networks Public networks an...

Страница 23: ...rface follow these steps 1 Select and double click the patient card in the patient list The Image Viewer tab is displayed 2 In the Image Viewer tab click or to access the Cephalometric Acquisition int...

Страница 24: ...20 Chapter 4 Getting Started...

Страница 25: ...nit and Setting the Acquisition Parameters To set the acquisition parameters follow these steps 1 On the unit position the head clamps manually for the lateral exam The lateral exam option becomes act...

Страница 26: ...to your patient type click the Parameter button Select the appropriate parameters Click and select Memorize Anatomy setting if you want to save the new parameter settings as future default settings Im...

Страница 27: ...lders 3 Pull out at the top part of a head clamp bar to extend both bars 4 Ask the patient to do the following Move forward Stand up straight Place both ears in between the head clamps 5 On the positi...

Страница 28: ...halometric Images 7 Lower the nasion support to a vertical position 8 Use the Frankfort positioning indicator as a visual aid to adjust the up or down inclination of the patient head for a Frankfort p...

Страница 29: ...ing software 3 Check the image quality if satisfactory remove the ear cones and the nasion support and release the patient X ray Dose Emission Information Compliance with EURATOM 97 43 Directive You c...

Страница 30: ...meters To set the acquisition parameters follow these steps 1 On the unit position the head clamps manually for the frontal exam The frontal AP exam option becomes active on the Cephalometric Acquisit...

Страница 31: ...e the new parameter settings as future default settings Preparing and Positioning the Adult and Pediatric Patient To prepare and position the patient follow these steps 1 Ask the patient to remove all...

Страница 32: ...frontal PA facing the cephalometric sensor Place both ears in between the head clamps 5 On the control panel press and hold to level the ear cones to the patient s auditory canals 6 Gently push in at...

Страница 33: ...CS 8100SC Family User Guide SM987 _Ed 01 29 Figure 5 3 Frontal AP Figure 5 4 Frontal PA...

Страница 34: ...eave the X ray room and close the door You must keep visual contact with the patient during acquisition Figure 6 Frontal AP Figure 7 Frontal PA Important If you have a problem that requires you to sto...

Страница 35: ...ng software 3 Check the image quality if satisfactory remove the ear cones and the nasion support and release the patient X ray Dose Emission Information Compliance with EURATOM 97 43 Directive You ca...

Страница 36: ...meters follow these steps 1 On the unit position the head clamps manually for an oblique exam The oblique exam option becomes active 2 On the Cephalometric Acquisition interface select the appropriate...

Страница 37: ...remove all metal objects 2 Ask the patient to wear a lead apron with a thyroid collar Ensure that the apron lays flat across the patient s shoulders 3 Pull out at the top part of a head clamp bar to e...

Страница 38: ...o fit the ear cones into the ear auditory canals 7 Lower the nasion support to a vertical position Launching the X ray To launch the X ray follow these steps 1 Leave the X ray room and close the door...

Страница 39: ...ng software 3 Check the image quality if satisfactory remove the ear cones and the nasion support and release the patient X ray Dose Emission Information Compliance with EURATOM 97 43 Directive You ca...

Страница 40: ...Parameters To set the acquisition parameters follow these steps 1 On the unit position the head clamps manually for a frontal AP exam The frontal AP exam option becomes active 2 On the Cephalometric A...

Страница 41: ...e the new parameter settings as future default settings Preparing and Positioning the Adult and Pediatric Patient To prepare and position the patient follow these steps 1 Ask the patient to remove all...

Страница 42: ...up straight Place both ears in between the head clamps 5 On the control panel press and hold to level the ear cones to the patient s auditory canals 6 Gently push in at the top part of a head clamp b...

Страница 43: ...llow these steps 1 Leave the X ray room and close the door You must keep visual contact with the patient during acquisition Important If you have a problem that requires you to stop the acquisition re...

Страница 44: ...ng software 3 Check the image quality if satisfactory remove the ear cones and the nasion support and release the patient X ray Dose Emission Information Compliance with EURATOM 97 43 Directive You ca...

Страница 45: ...e acquisition parameters follow these steps 1 On the unit position the head clamps manually for a frontal AP exam 2 Remove the cap A take the carpus panel B and push it C into the magnetic carpus pane...

Страница 46: ...s not adapted to your patient type click the Parameter button Select the appropriate parameters Click and select Memorize Anatomy setting if you want to save the new parameter settings as future defau...

Страница 47: ...patient s shoulders 3 Ask the patient to do the following Stand to the side and as far as possible from the cephalometric unit Open the hand fully and place it flat on the carpus panel IMPORTANT Make...

Страница 48: ...dicating X ray emission When the acquisition ends the Cephalometric Acquisition interface disappears and the acquired image is automatically transferred to the imaging software 3 Check the image quali...

Страница 49: ...emitted dose received by the patient You can use this information to calculate the effective dose received by the patient for the image The radiation emission dose is expressed in mGy cm2 This dose i...

Страница 50: ...46 Chapter 5 Acquiring Cephalometric Images...

Страница 51: ...ician Controlling the Image Quality To maintain optimum image quality the image quality must be controlled once a month To control the image quality follow these steps 1 On your desktop double click T...

Страница 52: ...48 Chapter 6 Maintenance 3 Select the desired test and follow the on screen instructions...

Страница 53: ...n prematurely Relaunch the acquisition and hold the exposure button until the end of the acquisition cycle Message Description Action X ray tube cooling Cooling in progress Wait until the Generator Co...

Страница 54: ...50 Chapter 7 Troubleshooting...

Страница 55: ...ntatives Authorized Representative in the European Community Carestream Health France 1 rue Galil e 93192 Noisy Le Grand Cedex France Representante no Brasil Carestream do Brasil Com rcio e Servi os d...

Страница 56: ...52 Chapter 8 Contact Information...

Отзывы: