Carefree of Colorado
4
052548-301r13
A
WNING
C
ALIBRATION
P
ROCEDURE
If the awnings do not align at the intermediate positions (slide-out and window), it is necessary to run a
calibration routine to adjust the run and stop times for the awning.
1. The controls are programmed with default awning calibration values; this allows full awning operation
out-of-the-box.
2. The default calibration values are based on the average run times for the Paramount awning; these
values are close but not perfect.
3. The Slide-Out Cover and Window awning intermediate positions are set as a percentage of the awning
run time, 29% for Slide-Out Cover and 70% for Window.
4. Performing an awning calibration collects the actual extend and retract run times to allow the most
accurate awning operation.
5. For multiple awning installations, adjacent awnings must be aligned in the full extension position before
initiating awning calibrations, otherwise, a calibration will lock-in the difference in run times and will
cause misalignment at the intermediate positions.
6. For multiple awning installations, it is recommended that all awnings be calibrated at the same time
while operating on the same power source, i.e. do not calibrate one awning while operating on the
inverter and another while operating on the generator.
7. If a calibration is started and fails (stops) for any reason, the system resets the travel time and
maximum run time to the default values.
Procedure
Prior to starting the procedure, ensure that the motor limits are set correctly (refer to page 3).
The IN limit switch must be set to allow the motor to stall. Calibration will fail if the switch is set to stop
the motor.
The OUT limit switch is used to align adjacent awnings in the fully extended position before initiating
awning calibrations, otherwise, a calibration will lock-in the difference in run times and will cause
misalignment at the intermediate positions.
NOTICE
Do not continuously operate the awning more than 2-3 cycles maximum. The motor is
equipped with a thermal protection circuit to protect the motor from overheating. Operating the awning
repeatedly over a short time period may cause the circuit to sense an overheat condition and shut off the
motor. If this occurs, wait approximately 15 minutes to allow the motor to cool then resume the
procedure.