12. Warranty 

 

12.1 Scope 

 

This CuroCell

®

 system is covered by a 2-year warranty for manufacturing defects. The warranty 

does not apply to normal wear and tear or damage due to negligence or improper 

handling/care. 

 

12.2 Service and maintenance 

 

This CuroCell® mattress is a medical device, in accordance with MDD 93/42/EEC, that is used 

as an aid in preventing and treating pressure ulcers. For this reason, we recommend that the 

pump be regularly serviced and inspected to maintain functionality and performance. Like 

other technical devices, a pump that is properly cared for works better and lasts longer.  

 

Service and maintenance must always be performed by Care of Sweden or one of its 

authorised technicians. Only use spare parts that have been approved by Care of Sweden. Use 

of non-approved spare parts invalidates the warranty. 

 

A warranty claim must be submitted to Care of Sweden before the product is returned.  

 

Please contact Care of Sweden or your local dealer if you have questions regarding warranty 

and service. 

 

12.3 Life expectance 

 

This product´s expected life is estimated to be 5 years. 

 

 

13. Other information 

 

13.1 Disassembly and recycling 

 

 

Except for certain parts of the pumps, energy recovery is possible for almost all material in 

CuroCell

®

 products through incineration in waste incineration facilities.  

 

Pump:

 

A used CuroCell

®

 pump must not be disassembled. It must instead be taken to a recycling 

centre and sorted as electronic waste. 

 

Mattress:

 

A used CuroCell

®

 mattress must be taken to a recycling centre and sorted as combustible 

waste. 

 

For more information, please contact Care of Sweden or your local dealer. 

 

13.2 Returns and complaints

 

 

Complaints are to be reported to the supplier. Return of a product shall follow the supplier’s 

instructions and can only be done after the complaint has been reported. Damages due to the 

transportation should be reported to the transportation agent.

 

Содержание CuroCell 4

Страница 1: ...User manual 2019 04 26 CuroCell 4 Alternating pressure system Item number user manual 95 001044...

Страница 2: ...roduction 4 Product description 6 Assembly Installation 8 Operation 9 Cleaning and reconditioning 11 Storage 12 Maintenance 13 Troubleshooting 14 Technical description 15 Spare parts 17 Options and ac...

Страница 3: ...pump power cord or plug is defective the pump casing is damaged or it is not functioning properly Contact a service technician for examination and repair 6 Regularly check product functionality throug...

Страница 4: ...ing them immediately to us here at Care of Sweden The system has been tested and approved according to the following standards IEC 600601 1 IEC 60601 1 2 SS EN ISO 12182 SS EN ISO 14971 SS EN ISO 1099...

Страница 5: ...u can order a copy from our Customer services by sending your details to info careofsweden se NOTE For certain patients such as amputees are the recommended minimum weight not valid These users may ho...

Страница 6: ...on 2 1 Pump and mattress 1 CPR rapid deflation a Head b Foot 2 Pump 3 Mattress 4 Pump connector 1a Tubing system with CPR in head 1b Tubing system with CPR in foot With the optional heel section is th...

Страница 7: ...t care repositioning transferring in and out of bed Turn off this function by pressing the button It will return automatically to cycling after approx 30 minutes 5 Low pressure LOW PRESSURE The pump h...

Страница 8: ...d correctly 2 Hang the pump at the foot end of the bed or place it on a flat steady surface Route the power cord so that there is no risk of it causing someone to trip being run over by the bed wheels...

Страница 9: ...prescriber or other authorized personnel for appropriate setting 1 Use the comfort dial to set a suitable air pressure based on the settings table on the pump 2 When the green indicator lamp for norm...

Страница 10: ...til the pressure is corrected and reset See section 8 for troubleshooting 4 5 CPR In the event of an emergency requiring CPR cardiopulmonary resuscitation Quickly pull the CPR strap remove the quick c...

Страница 11: ...alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 If using a different agent choose one that does not affect the pump housing MATTRESS COVER Covers can be wiped of...

Страница 12: ...tubes and the CPR valve with a mild cleaning solution for this purpose such as alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 Let it dry 5 Wipe off and disinfect...

Страница 13: ...parts 7 2 Changing fuses 1 Pull the plug out of the electrical socket before replacing fuses 2 Remove the cover for the fuses with a screwdriver Pull out the fuse holder 3 Fit a new fuse of the same t...

Страница 14: ...ew minutes Do a hand check Refer to section 4 3 Check that the CPR valve valves are properly closed Mattress moves around Check that the air mattress is fastened to the bed frame with the straps under...

Страница 15: ...35 C Storage 15 C 50 C Shipping 15 C 70 C Humidity Operation 20 80 non condensing Storage 10 90 non condensing Atmospheric pressure 700hPa 1060hPa Classification Class II Type BF IP21 MATTRESS SPECIFI...

Страница 16: ...ycling Read the user manual Machine wash at 70 C CE marked acc to MDD 93 42 EEC Machine wash at 95 C Directly on bed base Tumble dry Do not iron Recommended user weight Patient information category Wi...

Страница 17: ...10 CC 916216 CC 907430 CC 905510 120x200 cm CC 906920 CC 916218 CC 907440 CC 905521 Art no Name Size CC 901310 Cell PU 80x21 cm CC 901311 Cell PU 85x21 cm CC 901312 Cell PU 90x21 cm CC 901313 Cell PU...

Страница 18: ...els of the bed NOTE This option is only available with new orders Sheet holder Specialised clips to which the sheet can be attached Six required per mattress 11 2 Accessories Art no Description and si...

Страница 19: ...t be submitted to Care of Sweden before the product is returned Please contact Care of Sweden or your local dealer if you have questions regarding warranty and service 12 3 Life expectance This produc...

Страница 20: ...ternet www careofsweden com Address Care of Sweden AB P O Box 146 SE 514 23 Tranemo SWEDEN Visit address Fabriksgatan 5A SE 514 33 Tranemo SWEDEN Cargo address Byns v g 4A SE 514 33 Tranemo SWEDEN Sup...

Отзывы: