xr 600
12
5.
SOFTWARE
After turning on, the treadmill automatically resets itself bringing the inclination to end run.
During this operation the oil-can under the motor cover sprays a little quantity of oil under the running belt.
The belt runs at low speed for about 10 sec.
At the end of the self-lubrication operation, the treadmill stops, brings it to inclination default value (see 5.2
Setup) and makes 3 beeps (2 short and 1 long) meaning that it is ready to be connected to ECG.
WARNING: switch the machine on and off once a day unless used.
5.1.
Connection to ECG
It’s possible to manage the treadmill by ECG selecting Trackmaster protocol.
Use only the RS232 cable supplied with the machine for connection to ECG.
When the treadmill is connected to ECG and the test starts, it performs one short beep sound and one long
beep sound when is disconnected.
5.2.
Setup
Treadmill’s software allows to set up some values/parameters.
Connect the treadmill to PC (Windows OS) with RS232 cable and open software “RunnerSetupSeriale”.
1)
Set up COM (on the left top);
2)
Click on green key
Start
;
3)
Turn on the treadmill;
4)
After about 40 sec. the treadmill is connected.
Содержание XR450R