background image

1

PRECAUTIONS

Before using this instrument, read this manual and 
pay special attention to all "WARNING" symbols: 

  IMPORTANT

  ELECTRICAL 

 

 

       WARNING 

INTRODUCTION

Thank you for purchasing our Detecto Model 
VET330 Digital Veterinary Scale.  The 
VET330 is equipped with a rechargeable 
battery pack that (after 14 hours of charging) 
is able to provide approximate 8 hours of 
continuous use.   

This manual will guide you through setup and 
operation of your scale.  Please read it 
thoroughly before attempting to operate this 
scale and keep it handy for future reference. 

ÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜ

FCC COMPLIANCE STATEMENT  

WARNING! 

This equipment generates uses and 

can radiate radio frequency and if not installed 
and used in accordance with the instruction 
manual, may cause interference to radio 
communications.  It has been tested and found to 
comply with the limits for a Class A computing 
device pursuant to Subpart J of Part 15 of FCC 
rules, which are designed to provide reasonable 
protection against such interference when 
operated in a commercial environment.  Operation 
of this equipment in a residential area may cause 
interference in which case the user will be 
responsible to take whatever measures necessary 
to correct the interference. 

You may find the booklet "How to Identify and Resolve 
Radio TV Interference Problems" prepared by the 
Federal Communications Commission helpful.  It is 
available from the U.S. Government Printing Office, 
Washington, D.C. 20402, stock No. 001-000-00315-4. 

ÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜÜ

All rights reserved.  Reproduction or use, without 
expressed written permission, of editorial or pictorial 
content, in any manner, is prohibited.  No patent 
liability is assumed with respect to the use of the 
information contained herein.  While every precaution 
has been taken in the preparation of this manual, the 
Seller assumes no responsibility for errors or 
omissions.  Neither is any liability assumed for 
damages resulting from use of the information 
contained herein.  All instructions and diagrams have 
been checked for accuracy and ease of application; 
however, success and safety in working with tools 
depend to a great extent upon the individual accuracy, 
skill and caution.  For this reason the Seller is not able 
to guarantee the result of any procedure contained 
herein.  Nor can they assume responsibility for any 
damage to property or injury to persons occasioned 
from the procedures.  Persons engaging the 
procedures do so entirely at their own risk. 

TABLE OF CONTENTS 

Introduction ………………………………….. 1

Specifications.………….………….………… 1

Installation………………………………….… 2

Display Functions ……..……..…..…………. 3

Key Functions …………...………………….. 4

Operation ……………………………………. 5

Configuration ………………..………………. 6

Gravity Compensation……………………… 7

Display Message …….…..………..……….. 8

Care and Maintenance….…..…………..…..  8

SPECIFICATIONS

Weight Display: LCD, 7 Digit, with decimal 1.0” 

Characters

Dimensions of 
Display head: 

10.63" W x 3.54" D x 1.77" H 

(270 mm x 90 mm x 45 mm) 

Platform Size: 

36" W x 22" D x 1.97”H 

(900 mm x 550 mm x 50 mm) 

Zero: 

Established on power up 
routine and maintained by 
auto-zero circuitry. 

Power: 

Built-in rechargeable battery 
pack (7.2VDC/1200mA) or 120 
VAC 60Hz  powering a 15 
VDC 300 mA wall plug-in 
UL/CUL listed power supply 

Tare: 

100% of full scale capacity 

Temperature: 

40 to 105°F (5°to 35°C) 

Humidity: 

25% ~95% RH 

Capacity and 
Division:

330lb x 0.2lb,  150kg x 100g 

Keys:

HOLD, UNIT, ON/ZERO/OFF, 
TARE

Features: 

Low battery indicator, Power 
saving selectable timing auto 
shut-off

Weight: 

52 Lbs (23.5 kg) 

Serial Number

_______________________

Date of Purchase 

____________________

Purchased Form

_____________________

___________________________________
___________________________________

RETAIN THIS INFORMATION FOR FUTURE USE 

Содержание VET330

Страница 1: ...MODEL VET330 DIGITAL VETERINARY SCALE Operation Manual CARDINAL SCALE MFG CO 1961 M045 O1 Rev A PO BOX 151 WEBB CITY MO 64870 Printed in USA 10 05 PH 417 673 4631 FAX 417 673 5001 www detectoscale com...

Страница 2: ......

Страница 3: ...nformation contained herein While every precaution has been taken in the preparation of this manual the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for da...

Страница 4: ...trical outlet The scale is now ready for operation BATTERY PACK The scale uses a 7 2VDC 1200 mA built in rechargeable battery pack The VET330 can operate for approximate 8 hours of continuous use with...

Страница 5: ...weight display is stable This is turned on when a negative minus weight is displayed This is turned on when the scale weight has been zeroed This is turned on when the battery pack is near the point...

Страница 6: ...s of measurement if selected during configuration of the scale 2 Press to select menu in the Configuration mode ON ZERO OFF 1 Press and release to turn on scale 2 Press and release to turn the scale o...

Страница 7: ...item to be weighed on the scale platform Wait a moment for the scale display to stabilize then read the weight TO RE ZERO THE WEIGHT DISPLAY To re ZERO the weight display press the ZERO key and contin...

Страница 8: ...change to On or Disable display will change to OFF 4 Press the HOLD key The display will change to Unit 5 Proceed to AUTOMATIC SHUTOFF To select lb pounds weighing units 1 With the display showing Uni...

Страница 9: ...nging in most locations In the event that the factory settings do not meet the requirements of your location contact the factory for the value for your location With GrAu enable from the function sett...

Страница 10: ...cale or other extreme shock DO NOT submerge scale or display in water pour or spray water directly on them DO NOT use acetone thinner or other volatile solvents for cleaning DO NOT expose scale or dis...

Страница 11: ...9...

Страница 12: ...10...

Отзывы: