background image

SETUP AND CALIBRATION, Cont.

UNLOAD WEIGHT

With the display showing 

X/G

, remove the 2 lb test weight from the scale tray. Allow

approximately five seconds for the scale to stabilize, then press the 

ON/TARE 

key to

continue the calibration. Dashes will be displayed from the left to the right of the display
momentarily, then the display will change to 

$6+

.

AUTOMATIC SHUTOFF

With the display showing 

$6+

, press the hidden

 

key to display the current setting. Press

the hidden

 

key until the desired number of minutes of inactivity before the scale will

automatically shutoff is displayed. Values of 1, 2, 5, 10, or 15 minutes or OFF are
available. Selecting OFF will disable the automatic shutoff feature. Press the 

ON / TARE

key to save the setting.

POWER UP ZERO 

The display will show 

3X2

. Press the hidden key to display the current setting. Press the

hidden

 

key to select 

<(6

to enable or

QR

to disable. Press the 

ON / TARE 

key to save the

setting.

DONE 

The scale will briefly display 

'1(

, then reset to the Operation weight mode.

SETUP REVIEW

The Setup Review mode allows you to review and change the Automatic Shutoff operational
parameters as desired without having to enter the setup and calibration mode. To enter the
setup review mode, you need to turn the scale off by pressing the hidden

 

and 

ON-TARE

 keys

simultaneously and then pressing and holding the 

ON-TARE 

key until the red indicator for 0 oz

begins to flash. After the red indicator begins to flash, release the 

ON-TARE

 key. The display

will show 

$6+

, the prompt for automatic shutoff.  Refer to the instructions listed in the Setup

and Calibration section  for information on how to change the Automatic Shutoff setting. 

4

Location of
Calibration
Switch

Hidden Key

If 

(U$

 is displayed during the 

/2G

 or 

XOG

 calibration sequence, remove the test

weight from the scale and verify that it is the correct weight (2 lbs) or insure that
the scale is empty and nothing is touching the scale tray. The display will return to

Отзывы: