background image

8529-M635-O1

y

 DS-30 

Page 3

PRECAUTIONS

Before using this instrument, read this 
manual and pay special attention to all 
"WARNING" symbols: 

IMPORTANT 

 ELECTRICAL 

 WARNING 

INTRODUCTION

Thank you for purchasing our Detecto DS Series Price Computing Scale.  Your scale has been 
designed to operate from 115 VAC 50/60 Hz (optional 230 VAC 50/60 Hz) or with the 

included

rechargeable battery pack.  The battery pack is able to provide 100 hours continuous operation 
(with backlight on) or 200 hours continuous operation (with backlight off). 

This manual will guide you through setup and operation of your scale.  Please read it 
thoroughly before attempting to operate this scale and keep it handy for future reference. 

FCC COMPLIANCE STATEMENT  

WARNING! 

This equipment generates uses and can radiate radio frequency and if not 

installed and used in accordance with the instruction manual, may cause interference to radio 
communications.  It has been tested and found to comply with the limits for a Class A 
computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide 
reasonable protection against such interference when operated in a commercial environment.
Operation of this equipment in a residential area may cause interference in which case the 
user will be responsible to take whatever measures necessary to correct the interference. 

You may find the booklet "How to Identify and Resolve Radio TV Interference Problems" 
prepared by the Federal Communications Commission helpful.  It is available from the U.S. 
Government Printing Office, Washington, D.C. 20402.  Stock No. 001-000-00315-4. 

All rights reserved.  Reproduction or use, without expressed written permission, of editorial or 
pictorial content, in any manner, is prohibited.  No patent liability is assumed with respect to 
the use of the information contained herein. While every precaution has been taken in the 
preparation of this manual, the Seller assumes no responsibility for errors or omissions.  
Neither is any liability assumed for damages resulting from use of the information contained 
herein.  All instructions and diagrams have been checked for accuracy and ease of application; 
however, success and safety in working with tools depend to a great extent upon the individual 
accuracy, skill and caution.  For this reason the Seller is not able to guarantee the result of any 
procedure contained herein.  Nor can they assume responsibility for any damage to property or 
injury to persons occasioned from the procedures.  Persons engaging the procedures do so 
entirely at their own risk. 

Serial Number

_______________________

Date of Purchase 

____________________

Purchased From

_____________________

___________________________________

___________________________________

RETAIN THIS INFORMATION FOR FUTURE USE 

Содержание DS Series

Страница 1: ...nual Cardinal Scale Manufacturing Co 8529 M635 01 Rev B PO BOX 151 WEBB CITY MO 64870 Printed in USA 04 09 PH 417 673 4631 FAX 417 673 5001 www detectoscale com Technical Support Ph 866 254 8261 y techsupport cardet com This Document is Hosted by www oldwillknottscales com ...

Страница 2: ...8529 M635 O1 y DS 30 Page 2 ...

Страница 3: ... to take whatever measures necessary to correct the interference You may find the booklet How to Identify and Resolve Radio TV Interference Problems prepared by the Federal Communications Commission helpful It is available from the U S Government Printing Office Washington D C 20402 Stock No 001 000 00315 4 All rights reserved Reproduction or use without expressed written permission of editorial o...

Страница 4: ...e w w w w w w w w w w w w w w w w w w w w w w w w 5 PrePack Operation w w w w w w w w w w w w w w w w w w w w w w w 5 Tare Operation To Obtain Net Weight w w w w w w w 5 Metric Conversion w w w w w w w w w w w w w w w w w w w w w w w 5 CALIBRATION w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w 6 CALIBRATION SEAL INSTALLATION w w w w w w w w w w w w w 9 ERROR AND STATUS DISPLAYS w w ...

Страница 5: ...mounting feet and adjust them as required to center the bubble and attain a level scale Once the scale is level lock the mounting feet in place by tightening the adjustment locking rings against the bottom of the scale Power Connection The scale contains a power supply that converts the 110 120 220 240 VAC 50 60Hz wall supply to the power required by the scale circuitry The power supply also conta...

Страница 6: ...ght mode UNITS Pressing this key will display the current weighing units To change to a different weighing unit press the UNITS key then the corresponding key on the numeric keypad for the weighing unit desired 1 kilogram mode kg 2 100g mode 3 pounds mode The currently selected weighing unit is indicated by illuminating and blinking the kg 100g or lb annunciator PRE PACK Pressing the PREPACK key a...

Страница 7: ...ght is determined by subtracting the stored tare weight from the gross or scale weight The tare weight usually the weight of the container is entered using the tare key Note that the NET annunciator is only active when a zero tare weight or tare weight value is stored and the display is in the weight mode as shown by the illumination of the kg 100g or lb annunciator kg The kg annunciator is locate...

Страница 8: ...nnunciator LED s to allow the operator to make a visual verification that the display is operational After completion of the lamp test the weight display will show zero weight indicating the scale is ready for use Display Backlight Auto Backlight Press the ZERO key The WEIGHT display will show CENTR With CENTR displayed press the 4 key on the numeric keypad When the weight is over 10 divisions or ...

Страница 9: ...eration For repetitive price computing of commodities with the same unit price 1 Enter tare if so desired as outlined in Tare Operation Tare entry will be retained in PREPACK mode 2 Enter unit price and press the PREPACK key The PREPACK annunciator will illuminate 3 Place commodities on scale and proceed with operation 4 When the prepacking operation is ended press the PREPACK key to clear unit pr...

Страница 10: ...o pictures A and B remove the 4 blue dust shields from the weighbridge posts and turn the scale upside down 3 Using picture C as a guide locate the 4 screws securing the top housing to the bottom housing and remove the screws 4 Grasping the scale so that you can hold the 2 housings together turn the scale right side up and with the rear display towards you 5 Referring to picture D lift the top hou...

Страница 11: ...8529 M635 O1 y DS 30 Page 7 Housing Screws CALIBRATION CONT Dust Shields Calibration Switch Calibrate Normal Calibration Switch A B C D F E ...

Страница 12: ...de NOTE If you are operating the scale using AC power grasp the scale so that you can hold the 2 housings together and remove the AC power cord also 2 Turn the scale so that the rear display is towards you Referring to picture D lift the top housing off the bottom and tip the rear of it forward away from you To avoid damaging the keypad cable only lift the housing up enough to clear the internal c...

Страница 13: ...ned to accept a lead and wire security seal to prevent unauthorized access to the calibration adjustments Refer to the figure below for details on the installation of the seal Thread the sealing wire through the hole in the post in the center of the scale as shown Pull the wire tight and install the lead seal The scale housings cannot be separated without damaging the seal Lead and Wire Seal Botto...

Страница 14: ...service assistance you should make some initial checks to verify that a problem does exist The following describes several types of symptoms along with suggested remedies PROBLEM POSSIBLE SOLUTIONS Display does not turn on AC Operation x Is the AC power cord fully inserted into the wall receptacle x Check wall receptacle for proper AC power Try another electrical appliance in the same receptacle D...

Страница 15: ...8529 M635 O1 y DS 30 Page 11 ...

Страница 16: ...8529 M635 O1 y DS 30 Page 12 ...

Отзывы: