background image

8525-0358-0M Rev-A 

 DR550C Operation 

INSTALLATION 

Unpacking 

Before beginning installation of your scale, make certain the instrument has been received in 
good condition.  When removing the scale from its packing, inspect it for signs of damage, 
such as exterior dents and scratches.  Keep the carton and packing material for return 
shipment if it should become necessary.  It is the responsibility of the purchaser to file all 
claims for any damages or loss incurred during transit. 
 

1. 

Remove the scale from the shipping carton and inspect it for any signs of damage. 

2. 

Plug-in the supplied 9VDC power supply or install (6) AA 1.5V alkaline battery.  Refer to the 
POWER SUPPLY or BATTERY sections of this manual for more instruction. 

3. 

Place the scale on a flat level surface, such as a table or bench. 

4. 

The scale is now ready for use. 

 

Power Supply 

To apply power to the scale using the supplied 9VDC, 100 mA power supply, insert the plug 
from the power supply cable into the power jack on the back of the scale and then plug power 
supply into the proper electrical outlet.  The scale is now ready for operation.   
 

Battery 

The scale can use (6) AA 1.5V alkaline batteries (

not included

).  If you wish to operate the 

scale from batteries, you must first obtain and install the batteries.  The batteries are contained 
in a cavity inside the scale. Access is via a removable door on the top cover of the scale. 
 

Battery Installation 

The DR550C Digital Scale operates with (6) “AA” 
batteries (Alkaline preferred). 
 

1. 

Place unit upright on a flat surface and lift platform 
from top of scale. 

2. 

Remove battery compartment door and insert 
batteries into compartment.  Make certain to observe 
the correct polarity. 

3. 

Replace compartment door and platform cover on 
scale. 

 
 

Mounting the Unit 

1. 

Mount bracket to wall using (2) screws that are 
appropriate anchors for the surface being mounted 
to. 

2. 

Lower control panel into mounted bracket.  Insert flat 
tip screws (included) through round holes in 
mounting bracket and drive the screws into existing 
threaded holes in lower half of control panel to 
secure control panel to bracket. 

 

Содержание DR550C

Страница 1: ...ion 1 MODEL DR550C DIGITAL SCALE Operation Manual CARDINAL SCALE MFG CO 8525 0358 0M Rev A 203 E Daugherty Webb City MO 64870 USA 02 15 Ph 417 673 4631 Fax 417 673 2153 www detecto com Technical Support Ph 866 254 8261 tech cardet com ...

Страница 2: ...omputing device pursuant to Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference You may find the booklet How to Identi...

Страница 3: ...vision 550lb x 0 2lb 250kg x 0 1kg Keys ON OFF NET GROSS UNIT TARE Features Low battery indicator Power saving selectable timing auto shut off CARE AND MAINTENANCE The heart of the DR550C Digital Scale is 4 precision load cells located in the four corners of the scale base It will provide accurate operation indefinitely if protected against overload of scale capacity dropping items on scale or oth...

Страница 4: ...wer supply cable into the power jack on the back of the scale and then plug power supply into the proper electrical outlet The scale is now ready for operation Battery The scale can use 6 AA 1 5V alkaline batteries not included If you wish to operate the scale from batteries you must first obtain and install the batteries The batteries are contained in a cavity inside the scale Access is via a rem...

Страница 5: ... minus weight is displayed lb Red LED at the right of lb will be turned on to indicate the displayed weight is in pounds kg Red LED at the right of kg will be turned on to indicate the displayed weight is in kilograms Lo Low Battery When the batteries are near the point they need to be replaced a low battery indicator on the display will turn on If the voltage drops too low for accurate weighing t...

Страница 6: ...anty Turn the Scale On Press the ON OFF key to turn the scale on The scale will display 8888 then change to the selected weighing units Select the Weighing Unit Press the UNIT key to alternate between the selected weighing units Weighing an Item Place the item to be weighed on the scale platform Wait a moment for the scale display to stabilize then read the weight To Re Zero the Weight Display To ...

Страница 7: ...With the display showing Unit press the TARE key 2 The display will change to show AOFF 3 Press the UNIT key to begin selection of the automatic shut off time in seconds 4 The display will change to show 120 5 Press the TARE key to toggle through the selections 120 180 240 300 or OFF 6 When the desired time is displayed press the UNIT key 7 The display will change to show AOFF 8 Proceed to Saving ...

Страница 8: ...8525 0358 0M Rev A DR550C Operation 6 ...