2
INSTALLATION
1. Remove the scale from its shipping container and inspect it for shipping damage. Should
evidence of damage be found, the carrier should be contacted at once. Retain the shipping
container for future storage or shipment of the scale.
2. Install the batteries. Refer to BATTERY REPLACEMENT section. If batteries are not to be
used, plug the optional AC power adapter into the power jack on the back of the scale.
3. Place the scale on a stable, vibration-free location away from direct sunlight and any rapidly
moving air source. If the AC power adapter is being used, make certain the cord is stored out of
the way of normal traffic.
4. Plug the optional AC power adapter (if used) into a 115 VAC 50/60 HZ grounded wall outlet.
5. The scale is now ready for use.
BATTERY REPLACEMENT
This instrument is designed for operation from either four
(4) AA Alkaline batteries or an optional AC power
adapter. A low battery signal is provided in the weight
display to indicate when the batteries should be
replaced. Remember to use only size AA Alkaline
batteries in the instrument.
1. Turn the scale bottom side up and remove the single
screw from the battery compartment cover. Remove the
cover from the base by lifting up and pulling outward as
shown.
2. Remove the old batteries and replace with fresh ones.
Make certain the
+
and
-
ends of the batteries match
the positions shown on the scale circuit boards as
shown. Replace the battery compartment cover and
retaining screw.
OPERATION
1.
TURN THE SCALE ON -
Press the
ON-TARE
key
.
2.
SELECT THE WEIGHING UNIT -
Press the
WT-UNIT
key to alternate between ounces and gram weight
displays. A red indicator light will illuminate to show
the selected units.
NOTE!
In Grams only mode, the
WT-UNIT
key is disabled.
3.
WEIGH -
Place the item to be weighed on the tray and
read the weight in the digital display.
4.
TO RE-ZERO THE WEIGHT DISPLAY -
Press the
ON-TARE
key. The instrument will zero up to the full
capacity of the scale.
The membrane keyboard is not to be operated with pointed objects (pencils, pens,
fingernails, etc). Damage to keyboard resulting from this practice will
NOT
be
covered under warranty.
AUTOMATIC SHUT-OFF FEATURE
This scale is equipped with an automatic shut-off feature that helps prolong battery life by turning
the scale off after a predetermined period of inactivity. To turn the scale back on you must press
the
ON-TARE
key. The automatic shut-off feature is activated during the setup and calibration
procedure and can be set for 1, 2, 5, 10, or 15 minutes of inactivity before the scale will
automatically shut off. The automatic shut-off feature may be disabled by selecting OFF during
setup and calibration procedure.
Battery
Compartment
Cover
Pull cover
out and up
Batteries