10
Electrical connection
Before connecting the appliance make sure that the voltage and frequency rated on the data plate
conform to those of he mains supply.
THREEPHASE MAIN SWITCH
:
(fig. 3 pag. 2)
Connect the power cables directly to the door security switch
2/4/6 Threephase power supply
400V3~
TERMINAL BOARD CONNECTIONS
1
Earth binding post (mains supply)
2
Motor earthing wire (output)
3-4-5 Three phase motor output Opening- Closing- Common
6-7 Electronic braking device positive/negative
24Vdc
output
8-9
24Vac 10W
flashing warning lamps indicating gate in movement
9-10
24Vac 3W
output. Indicates that the gate/door is open.
11-12
24Vac 5W
output, powering external devices (Photoelectric cells, etc.)
13
FTCI
(contact N.C.) Safety and control devices input (photo-cells invert the travel direction when
an obstruction is detected) .
14
FTCS
(contact N.C.) Safety and control devices in input
(photoelectric cells stopping the gate when an obstruction is detected) The opening of this contact
will block all movement, during opening and closing, until the obstruction has been removed, due
to the safety device cutting in, the gate will then continue moving until it reaches a travel limit.
15
Common for all inputs and outputs (negative)
16
TD
(contact N.O.) Dynamic button input
“
Open-Close
”
17
Radio receiver antenna pole
18
Mass for radio receiver antenna
19
FCA
opening travel limit input (contact N.C.)
20
FCC
closing travel limit input (contact N.C.)
21
Common for all inputs and outputs (negative)
22
TA
(contact N.O.) Opening button input
23
TC
(contact N.O.) Closing button input
24
TB
(contact N.C.) Blocking button input.
25
TAL
Limited opening button. If the automatic re-closing function is inserted the closing movement
will be activated after the pause time has expired.
26-27
BSP
Passive safety input (N.C.)
If this contact is open the power supply to the controls (including the electronic card) will be inter-
rupted. Insert a normally closed contact which is able to support a load of
30Vdc 100mA
. This
safety device should be installed in addition to the normal active safety devices (Caution! This input
cannot be connected in series with the
FTCI
,
FTC
S
, TB
as they do not share the same common).
It could also be wired in series to a fixed position anti-crush buffer or be used an emergency device
in line with the local standards and regulations in force.
N.B.: ALL UNUSED NC CONTACTS MUST BE JUMPED
5
AP
.
3
4
1
2
Comune
CH.
M
TD
14
13
12
11
10
9
8
7
6
FTC_S
24V
.ac
LS
LP
FTC_I
24V
.ac
24V
.ac
TA
L
24
23
22
21
20
19
18
17
TB
TC
TA
FCC
FCA
+
PW
Jumper
TB
DC0343
CS1068B.01
BSP
AP
25 26
16
15
27
OUT EF
+
-
4
4
4
7
5
6
8
1
2
3
1 0
1 0
1 0
1 0
Opening
1 0
1 0
Closing
Scheda base
PRG384
13-09-2001
DC0343
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
YPR384B01CE
NO NO
NC
NO
NO
5