background image

ZVL195.01

S48D

28-01-04

RX16-100 

CARDIN  ELETTRONICA  spa 

Via Raffaello, 36- 31020 San Vendemiano (TV) Italy

Tel:  

+39/0438.404011-401818

Fax:  

+39/0438.401831

email (Italy): 

Sales.offi[email protected]

email (Europe): 

Sales.offi[email protected]

Http: 

www.cardin.it

The 

S48D

 series conforms to the essential requirements of the directive 

99/05/

CE

 and the technical reference standards have been applied. This product has 

been tried and tested in the manufacturer's laboratory, during the installation 

of the product follow the supplied indications carefully. 

Description

The 

S48D

 Radio control system consists of one or more transmitters and one or more 

receivers which can be combined to meet the specific needs of the system.

The 

S48D

 uses the random numbers system to generate the secret code. This system 

is base on the generation of a casual and secret code by the receiver (generated by a 

random numbers counter) and the insertion of this code into the transmitter/s (by means 

of a module which slots directly into the transmitter). The secret code is memorised 

by the receiver and transferred into the transmitter using a non volatile  EEPROM type 

memory  module.  This  encoding  system  has   

7.000.000 

possible  combinations,  and 

allows a different code (for different receivers) to be programmed into each available 

channel. The transmitter automatically switches off 15 seconds after the last command 

has been given.

Use

The 

S48D

 radio control allows the remote activation of electrical and electronic appliances 

with its best use in the following areas: automatic opening systems, alarm systems, and in 

all systems which require remote control activation (without wires) using secret codes.

Transmitter versions

TRQ048D08

 

8-channel transmitter 

 

TRQ048D16

 

16-channel transmitter 

 

TRQ048K10

 

100-channel transmitter

 

 

Receiver versions

RZQ048B16  

 

Multifunction receivers 16-channels

RZQ048K10  

 

Master card receivers expandible up to 100 channels

MEB048320

 

Expansion module with 32 relays (8 strips with 4 relays each) 

 

Interchangeable channel modules

MDC048400

 

Strip with 4 relays 

Accessory kit:

  

Slide on key pad cover and clips (fig. 3-4) - Battery 12V (fig.5)

Antenna

The installation of the antenna is fundamental, connected to the receiver it represents 

the reception point for the radio control. When installing the antenna the following points 

should be observed:

-  Only use a tuned antenna connected to the receiver using a coaxial cable 

RG58

 (imped-

ance 

50

Ω

) with a maximum length of 

15 m

;

-  The antenna should be positioned out of doors in the highest possible point, visible and 

away from metal structures.

Note

: If for some particular reason it is not possible to fit an antenna, a reasonable per-

formance can be obtained by connecting a 

2,5

 

m.

 piece of single pole conductor wire 

(

Ø1 mm.

) to the receiver.

Warning!

 The receivers must only be powered by a safety power pack. The use of 

non safety power packs could provoke damage to the system.

16-Channel receivers (see fig.8)

-  The receiver is  preset for the insertion of up to four expansion modules (4 relays per 

card allowing combinations of 4-8-12 and 16 channels).

-  It is fitted with a 

TX-LINK

 docking connection for the insertion of 

S48D 

radio controls, a 

connection marked "

M1

" for the insertion of memory modules (see relative paragraph) and a 

dip "

D1

" which controls the code generation and code to memory transfer functions.

99-Channel receivers (see fig.9)

-  The receiver master card is fitted with a connection marked "

CON1

" for the insertion 

of channel modules and can be expanded using modular expansion boards  (max. 

3  cards) each one of which has 32 relays 

-  It is fitted with a 

TX-LINK

 docking connection for the insertion of 

S48D 

radio controls, a 

connection marked "

M1

" for the insertion of memory modules (see relative paragraph) 

and a dip "

D1

" which controls the code generation and code to memory transfer 

functions.

-  The  selection  of  the  blocks  of  relays  situated  on  the  expansion  boards    can  be 

regulated using the  Jumper "

J1

". 

Generating the user code in the radiocontrol system RX48 (fig. 8-9)

1)  Switch on the power supply to the receiver 

2)  Move dip 1 of the dip-switch "

D1

" (fig.8-9) to the "

ON

" position (starts generating 

random codes), after about 10 seconds move it back to the "

OFF

" position. 

3)  Move dip 2 of the dip-switch "

D1

" (fig.8-9) to the "

ON

" position (from this point the 

secret code is already memorised in the code memory module of the receiver). Move 

dip 2 to the "

OFF

" position.

4)  Insert the transmitter into the 

TX-LINK

 docking connection on the receiver, select 

the channel which is to be memorised and press the 

"INV"

 key (fig. 3). If the code 

has been correctly learnt a led "

LD

" will light up on the receiver (fig.8-9) and the 

transmitter buzzer will sound.

Using the 16 channel receivers

 (fig.6a - 6e):

-  Press the button with arrow pointing upwards (fig.6a) to start from the highest number 

"

16

" and then scroll the numbers using the button with the arrow pointing downwards  

(fig.6b) until the desired channel number appears on the display e.g. 10.

-  Press the button with arrow pointing downwards (fig.6b) to start from the lowest number 

and then scroll the numbers using the button with the arrow pointing upwards (fig.6a) 

until the desired channel number appears on the display.

-  To memorise a channel (e.g. 10) press the "

mem

" button (fig.6c). The memorised 

channel can be recalled by pressing the "

mem

" button when the 

transmitter is off

.

-  Press the "

INV

" button (fig.6d) to activate the relay which corresponds to the chosen 

channel (the transmission is signalled by a symbol which appears on the right of the 

display). If this button is pressed when the transmitter is off, the channel which was 

last transmitted will be recalled.

-  The battery symbol (fig.6e) appears when the Tx battery is flat.

Using the 100 channel receivers

 (fig.7a - 7c):

-  Press a two digit number on the key board (fig.7c), (first the five and then the three 

to make number 53 as shown in the example) 

-  To memorise a channel (e.g. 53) press the "

mem

" button (fig.7a). The memorised 

channel  can  be  recalled  by  pressing  the  "

mem

"  button  when  the 

transmitter  is 

off

.

-  Press the "

INV

" button (fig.7b) to activate the relay which corresponds to the chosen 

channel (the transmission is signalled by a symbol which appears on the right of the 

display). Pressing this button or one of the buttons from 0 to 9 when the transmitter 

is off will recall the channel which was last transmitted.

-  The battery symbol (fig.7c) appears when the Tx battery is flat.

Memory modules M1:

Code  number  93C46  for  RX16  channels  -  Code  number  93C66  for  RX100 

channels

This is extractable, furnished with a non volatile EEPROM type memory and contains the 

system code. The programmed code is maintained in this module even in the absence 

of power, it is therefore possible to extract the module for maintenance purposes and 

reposition it inside another receiver which will automatically use the same code.

Duplicating a memory module  

1)  Remove the original memory module and insert the new one.

2)  Move dip 2 of the dip-switch  from the "

OFF

" position to the "

ON

" position then 

reposition it in "

OFF

" at this point the new module has been encoded with the same 

code as the original. Switch the power to the receiver "

OFF

" and "

ON

" to ensure the 

code has been memorised.

Channel functions for the S48 radio controls

 

Remember that the receiver can only respond to one signal at a time, it therefore follows 

that several channels cannot be activated simultaneously.

Attention

!

  

The 16-channel receiver is fitted with a jumper "

J1

" to allow it to be used with the 100-

channel transmitters for a maximum of three 16-channel receivers. The channel block 

selection (jumper “

J1

” ) must be carried out before powering up the receiver:

•  Jumper “

J1

” in position 1; the channel block from 1 to 16 is selected

•  Jumper “

J1

” not inserted; the channel block from 17 to 32 is selected

•  Jumper “

J1

” in position 2; the channel block from 33 to 48 is selected

 

Examples:

  

•  Jumper “

J1

” in position 1; activating CH1 on a 100-channel transmitter will activate

  relay CH1 on the 16-channel receiver;

•  Jumper “

J1

” not inserted; activating CH17 on a 100-channel transmitter will activate

  relay CH1 on the 16-channel receiver;

•  Jumper “

J1

” in position 2; activating CH33 on a 100-channel transmitter will activaterelay 

CH1 on the 16-channel receiver;

It is not possible to activate more than 48 channels (3 blocks of 16) using a 100-

channel transmitter

TECHNICAL DATA

Reception frequency

Attention: 

The transmission frequency of these products varies according to the approved 

frequency and eventual personalisation in the country of destination

Country 

Frequency  

Antenna

Only Italy & France 

30,875 MHz 

ANQ730

  

27,195 MHz 

ANQ727

USA 

27,195 MHz 

ANQ727

RECEIVER

-  local oscillation frequency tolerance ............................. 30 p.p.m. from -10° to +55°C

-  intermediate frequency ....................................................................................455 kHz

-  antenna impedance in input ................................................................................. 50 

Ω

-  sensibility(fine signal) ........................................................................................0.5  µ V

-  local oscillation emission .............................................................. <-70dBm (<100pW)

-  power supply  ................................................................................................... 230Vac

-  maximum power consumption at rest/activated relay ................................. 20/25 mA

-  maximum commutable power at the relay:

  load ac/dc  ................................................................................................... 60VA/24W  

   maximum voltage  ......................................................................................... 30Vac/dc

-  excitation/dropout delay ................................................................................... 150 ms

TRASMITTERS

-  carrier frequency tolerance ........................................... 30 p.p.m. from -10° to + 55°C

-  band width ............................................................................................ 10 kHz/± 5kHz

-  apparent radiated power ......................................................-10÷-7dBm (100-200µW)

-  apparent power harmonic products .................................................<-60 dBm (<1nW)

-  power output adjacent channel (± 10 kHz) ...................................<-37 dBm (<0.2µW)

-  modulation ...................................................................................................... AM/ASK

-  signal modulation ...............................................................................PCM, 1.3 ms/bit

-  power supply .............................................................................................. 12V ± 10%

-  maximum power consumption .........................................................................<40 mA

-  operating temperature range ...................................................................... - 20…70°C

-  relative humidity ................................................................................................ < 95%

RANDOM CODE QUARTZ RADIO CONTROLS WITH UP TO 100 CHANNELS 

MODEL