17
• Memorizing a channel code
• Deleting a channel code (via an associated mobile transceiver unit)
• Deleting the entire code memory (users)
• Memorizing ulterior mobile transceiver units
Attention!
Do not memorize the same channel on two interfaces close to each other (within the
same range of the mobile unit)
• Memorizing a channel code
- Move the mobile unit near to the interface
- Press and hold down the
MEMO
button on the fixed unit and LED
LGC
will flash slowly
- Press the button (channel) you wish to memorize on the mobile unit.
- The LED LGC on the fixed unit will flash rapidly and the mobile unit will emit two beeps.
- Press the button (channel) you wish to memorize on the mobile unit a second time. The LED
LGC
on the
interface will glow continuously and the mobile unit will emit two beeps. After a few moments Led
LGC
will switch off.
- Release the
MEMO
button. End of operation.
• Deleting a channel code (via an associated mobile transceiver unit)
- Move the mobile unit near to the interface.
- Press and hold down the
DEL
button on the fixed unit and LED
LGC
will flash rapidly.
- Press the button (channel) you wish to delete on the mobile unit.
- The LED
LGC
on the fixed unit will glow red continuously and the mobile unit will emit two beeps.
- After a few moments Led
LGC
will switch off.
- Release the
DEL
button. End of operation.
• Deleting the entire code memory content (users)
- Press and hold down the
MEMO
and
DEL
buttons for more than 4 seconds on the fixed unit.
- LED
LGC
will remain lit for the entire duration of the deletion, which lasts for about 3 seconds
- LED
LGC
will flash for a few moments and then switch off.
- Release the buttons. End of operation.
• Memorizing more mobile transceiver units by using a previously memorized mobile unit.
This procedure allows you to enable a new transceiver unit (from a remote position) with the help of a
transceiver unit that has already been memorised in the system. As the presence of the fixed-position
transceiver unit is not required this procedure can be carried out in any remote location (for example in
your chosen sales outlet).
Access to the "rapid memorizing" procedure can be activated or deactivated on the fixed-position
transceiver unit by inserting (or removing) the jumper R.MEMO:
• Jumper
R.MEMO
inserted: the rapid memorisation procedure is enabled.
• Jumper
R.MEMO
not inserted: the rapid memorisation procedure is disabled.
- Place the mobile unit A, that is already memorized in the fixed-position unit beside the new unit B (det. a).
- Using a pointed object press and release button
MR
on both mobile units (in sequence or simultane-
ously) (det. a).
- The blue and orange LEDS will flash on both mobile units (det. a).
- Press and release a channel button on unit A that is already present in the fixed-position unit (det. b).
- The new unit B will emit 2 confirmation beeps (det. c).
The mobile unit B will now command the fixed-position unit exactly like the mobile unit A.