A-1 INSTALLATION A-1
TECHNICAL SPECIFICATIONS
-
max. rated Output Amps @% Duty Cycle (Based on a 10 minute cycle) (Example; 200A@35% for DC Stick
and 250A@60% for AC/DC Balance TIG)
MODEL PowerMaster
256
Voltage 1~AC220/230/
240V
50/60Hz
INPUT
Fuse rating
42A
No-load Voltage
60 - 80V
Base current Adjusting Range
5~250A
AC balance
10%~90 %
AC Square Wave Frequency
20~250Hz
Rated Duty Cycle
60%
Pre Flow
0-10s
Start Amps
5-250A
AC
TIG
End Amps
5-250A
AMP Adjusting Range
5~250A
Rated Duty Cycle
60%
Current Up-slope Time
0~10S
Current Down-slope Time
0~25S
pulse(Base/AMP) Current Ratio
5%-95%
Pluse Time On
0.1~0.9
Pluse Frequency
0.5~25(25~250)Hz
post Flow Time
0~25s
Arc starting Mode
high frequency arc striking
Pre Flow
0-10s
Start Amps
5-250A
DC
TIG
End Amps
5-250A
No-load Voltage
70V
Current Range
5-200A
Rated Output Current
200A
DC
STICK
Rated Duty Cycle
35%
(Base) current Adjusting Range
20A~60A
CUT
Rated Duty Cycle
60%
Efficiency
≥
83%
Mass 28kg
Protection Class of enclosure
IP21S
Outline Dimensions mm
3
470x235x435