Troubleshooting and Additional Help
Refer to the list below in the unlikely event that you have problems with your
MCS 352.
Problem:
Solution:
1. The MCS 352 is not operational or
trips breaker immediately.
Polarity is reversed on vehicle battery connection.
Check connections for correct polarity. Check
circuit breaker on the side of the cabinet.
2. Pressure Gauge on the MCS 352
displays maximum pressure upon
start up.
Output and Return hoses may be reversed. Turn
Timer
to zero and check hoses for correct
connection.
3. Rapid loss of fuel from the MCS
352 reservoir.
Return hose connection may be incorrect, allowing
fuel/detergent to return to the vehicle's fuel tank.
4. Start/Run switch is on but
operation does not commence.
Check
Timer
. If no time is set, then turn the
Time
knob to set the run time.
5. The MCS 352 performs poorly.
Check all hoses and wires for cuts or frays.
Check cabinet for dents or impact markings.
Verify that the fuel filter has recently been
replaced. (Refer to the maintenance log in
Appendix A
to view dates of services
performed.)
ADDITIONAL HELP
Please verify that items 1- 5 above have been
reviewed before calling for additional
assistance.
In the unlikely event that problems persist with
the MCS 352, call: Your
Local Distributor
Or: MOTORVAC TECHNOLOGIES INC.
1431 S. VILLAGE WAY
SANTA ANA, CA 92705 USA
PHONE:
FAX:
E-MAIL:
WEB SITE: www.motorvac.com
714.558.4822
714.558.0754
Содержание MCS-352
Страница 1: ...SERVICE MANUAL MCS 352 DUAL SYSTEM FOR Gasoline Petrol and Diesel Engines MOTORVAC TECHNOLOGIES INC...
Страница 6: ...MCS 352 BACK VIEW POWER CORD DIESEL TANK GASOLINE TANK...
Страница 38: ...Diesel Cleaning Setup You are now ready to perform the Diesel cleaning procedure FIGURE C...
Страница 46: ...Diesel Cleaning Setup You are now ready to perform the Diesel cleaning procedure FIGURE C...
Страница 51: ...ELECTRICAL SCHEMATIC MCS 352 ECS 350...
Страница 52: ...FLOW CHART MCS 352 GAS SYSTEM ECS 350...
Страница 53: ...FLOW CHART MCS 352 DIESEL SYSTEM ECS 350...