1   Description 

1.1 

3216OT Over-Temperature Controller 

 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

1.2 

Keys 

 

Page Key 



The 

Page

 key is used to access level 2 when held down 

for 3 seconds. 

Scroll Key 



The 

Scroll

 key is used to scroll through the parameters. 

ACK 

Page + Scroll 



When pressed simultaneously the 

ACK

 function is used 

to: 

  Return to the Home Menu. 

  Acknowledge timer end. 

  Acknowledge an alarm if activated.  

Arrow Keys 



The arrow keys are used individually to adjust the 
selected parameters and in combination to run a program 

 
 
Note:

 

If a parameter is selected and no further action is taken, the display will time out and 

revert back to the home display in its working level after approximately 1 minute 

 

 

Power Output 

Indicator 

Scroll Key 

Down Key 

Up Key 

Alarm 

Indicator 

Hold Indicator 

Set point 

Temperature 

Measured 

Temperature 

Run Indicator 

Remote 

Indicator 

 (When configured) 

Scroll Key 

Page Key 

Содержание 3216OT

Страница 1: ...MC30 1 01 Operating Instructions Over Temperature Controller Type 3216OT Set point tracking English...

Страница 2: ...2 MC30 1 01...

Страница 3: ...ONTROLLER 4 1 2 KEYS 4 2 BASIC OPERATING INSTRUCTIONS 5 2 1 FURNACE OR OVEN CONTROLS 5 2 2 THE 3216OT OPERATION 5 2 3 BASIC OPERATION 5 2 4 OVER TEMPERATURE ALARM 6 2 5 RESETTING THE OVER TEMPERATURE...

Страница 4: ...ledge timer end Acknowledge an alarm if activated Arrow Keys The arrow keys are used individually to adjust the selected parameters and in combination to run a program Note If a parameter is selected...

Страница 5: ...splays the measured temperature and the over temperature set point The 3216OT set point tracking is connected internally to the main temperature controller The main controller transmits its set point...

Страница 6: ...sumes If the alarm is acknowledged when the temperature has dropped such that the over temperature condition no longer exists then the furnace or oven immediately resumes normal operation 2 6 Sensor B...

Страница 7: ...Basic Operation 7 MC30 1 01 4 Navigation Diagram 4 1 3216OT Read Write Read Write Read Write Read only Passcode 9 3 Sec LEVEL 1 ACCESS LEVEL 2 PV LEV PV SP GOTO SP A1 DHI ID units ID...

Страница 8: ...elephone 44 0 1433 620011 Fax 44 0 1433 621198 E mail info carbolite gero com For preventive maintenance repair and calibration of all Furnace and Oven products please contact Carbolite Engineering Se...

Отзывы: