CARBEST
Gas Hob & Sink Combination |
70177/70176
EN
18
It is possible to use a flexible connection hose, but it must be:
• Always be able to be inspected.
• Be protected against contact with hotable parts (e.g. burner cups).
• Be protected from the movable parts of the recessing (drawers, doors, etc.).
• Have a length which complies with the technical standards for each sector of reference.
• Avoid any type of mechanical stress on the flexible hoses during installation and use (protection against
traction, twisting, crushing, etc.). Replace the flexible hose within the expiration date.
• Once connected, check the gas circuit seal by using a non-corrosive fluid to detect any leaks. Do not use
a soap and water solution. DO NOT USE AN NAKED FLAME.
5.3 Electrical connections
LOW VOLTAGE DC12 V
CAUTION!
Any type of connection of the appliance to a power mains other than DC12V and indirect current (DC) is
strictly prohibited.Any other connection can pose a severe danger for the user of the appliance and cause
irreversible damage to the device itself.
Never connect the appliance to the main voltage (230 V~); this would result in the ultimate destruction of
the parts and a hazard to the user.
To connect the applinance, use a double cable and connect it to the terminal board.
The red terminal is the positive pole, while the black terminal is the negative pole. The power supply must
be correctly connected.
5.4 Fixing
The appliance must be fixed to the cabinet using screws as below chart:
70176_70177_Gas_Spüle_Kombi_EN.indd 18
70176_70177_Gas_Spüle_Kombi_EN.indd 18
14.03.22 17:16
14.03.22 17:16