Captron SENSORswitch CHT3-F Series Скачать руководство пользователя страница 3

Configuration help for SENSORswitch series CHT3-F

82140 Olching, Germany

Johann-G.-Gutenberg-Str. 7

www.captron.com

CAPTRON Electronic GmbH

CAPTRON Electronic GmbH 

Johann-G.-

Gutenberg-Str.7 

82140 Olching, Germany 

www.captron.com

 

  

 

 

 

Tel +49(0)8142-4488-

0 • Fax +49(0)8142

-4488-

100 • 

[email protected]

 

Geschäftsführer: Reinhard Bellm, Petra Bellm, Philip Bellm • München HRB 70962 • USt.

-ID Nr.: DE 129 310 850

 

 

Additional information & explanations on the previously described configuration items:

 

 

 

to 

1)

 

Output signal

 

- Dynamic:

 

The output signal is time-limited to 300ms, independent of the duration of actuation. 

 

 

 

- Static: 

 

The SENSORswitch switches as long as the button surface is touched (= permanent signal). 

 

to 

2)   

/  Mounting & dimensions 

 

 

„F“  

-  Front plate mounting  

            

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                          Legend: 

 

(A)    =   Sensor element 

(B)    =   locking ring (included in delivery) 

 

 

 

to 

3)

  /  LED control & connection diagrams: 

 

LED-control

 

- Semi-Automatic (P / N):

  

LED1 (e.g. green / operating state) can be controlled separately. 

  

 

 

 

 

 

When the SENSORswitch is actuated, LED1 goes out and LED2 (e.g. red / 

switching state) lights up 

 

- Manual (B): 

Both LED1 and LED2 can be controlled separately as required. 

 

 

Connection diagram: 

 

 

 

 

 

 

 

 

    

Connection diagram „P“

   

 

       

Connection diagram „B“

   

 

                 

Connection diagram „N“

 

  PNP-NO  //  Semi-Automatic  

 

       PNP-NO  //  Manual 

 

 

 

 NPN-NO  //  Semi-Automatic

  

 

 

 

 

 

 

- - -  PLEASE TURN OVER - - - 

 