use as a safety component in accordance with Machinery
Directive 2006/42/EC.
•
use outdoors.
•
use in potentially explosive atmospheres.
Technical specifications
Operating voltage
10…30 V
Load current
max. 400 mA
Output
PNP-NO
Output pulse
optionally dynamic
CHT12
Constant signal when actuated
approx. 300 ms
Toggle flip flop
Reverse polarity protection
Protection of all cables/lines
Short circuit protection
Protected against short circuit and
overload
Voltage drop
optionally dynamic
Max. 2 V at 400 mA
Max. 2 V at 200 mA
Power consumption
Max. 20 mA at 24 V / Max. 20 mA at 24
V
Operating temperature
-30...+70°C