background image

J130

2

INSTALLATION

- When installed the hood must not be less than

60 cm. above electric burners or 65 cm. above

gas or mixed burners.

If the instructions for the installation of the gas

cooking appliance specify a greater distance,

please take this into account.

Electrical Connection

- Before making the electrical connection, make

sure that the voltage of the electrical mains com-

plies with the value indicated on the rating sticker.

It is highly recommended that the connection be

made by a qualified electrician.

Unit Fitted with Plug

Insert the plug into an outlet that complies with the

electrical safety codes currently in effect.

Once inserted into the outlet, the plug must be

easily accessible. If you intend to connect the unit

directly to the electrical mains, remove the plug

and install a standard bipolar switch with a mini-

mum contact break of 3 mm.

Unit Not Fitted with a Plug

Install  a  standard  plug  or  a  standard  bipolar

switch with a minimum contact break of 3 mm.

The manufacturer will not be held liable for any

problems arising out of the failure to comply with

the foregoing instructions.

CLASS  2  APPLIANCES  DO  NOT  HAVE  TO  BE

EARTHED

Class 2 appliances labelled with the symbol in the

form of a double square must be connected as

follows:

BROWN

=

L

(current)

BLUE

=

N

(neutral)

UTILIZATION

The  hood  is  designed  to  be  utilized  either  for

suction version at external evacuation or filtering

version at internal recirculation.

SUCTION VERSION

EXTERNAL EXHAUST

The air is vented outdoors by a duct which must

be connected to exhaust hole Ø 120 mm. by the

connecting ring (A) Fig.1. The hood must not be

connected to fuel exaust flues or to a duct in which

hot air is circulated, or is utilized to remove the

fumes  from  appliances  stocked  by  an  energy

different from the electric one. Pay attention when

there is the contemporary functioning of an hood

and a burner or furnace depending from the air

of the surrounding (stocked by an energy different

from  the  electric  one),  because  the  hood,

suctioning, takes away from the surrounding the

air that the burner or the furnace need for the

combustion.

So,  for  a  sure  functioning,  provide  a  suitable

ventilation of the room by doors, windows or other

technical devices.

For the external exhaust you have to follow the

Authority’s rules. The external exhaust must not be

made in a flue, utilized for the combustible gas of

appliances not stocked by the electric energy.

FILTERING VERSION

INTERNAL RECYCLING

When  there  is  no  exhaust  duct  for  venting

outdoors, you can use a carbon filter. The air is

depurated  by  the  filter  and  put  again  in  the

surrounding. To use the appliance in this version,

proceded as follows:

-Insert the carbon filter "D" Fig. 2.

The air is vented outdoors by a duct Ø 120 mm.

passig through the wall units and connected to

the connecting ring (A).

MOUNTING THE HOOD

Once  the  hood  has  been  set  up  to  vent  or

recirculate the air, proceed with the installation

process.

- This appliance is designed to be installed within

a cabinet or other supporting structure.

- The cutout which must be made on the bottom

of the cabinet must have the dimensions shown

in Figure 4.

Tho mount the hood, proceed as follows:

- Remove the frame by pushing the buttons "B"

Fig. 3.

*Note:  For  the  version  with  halogen

lamps,switch off the connectors "F" Fig. 3.1.

- Insert the hood into the cutout.

- Insert the screws supplied with the hood intro

the "C" holes and tighten the hood to the cabinet

(Fig. 4).

- Remount the frame

*Note:  For  the  version  with  halogen  lamps,

connect the spot lights before remounting the

frame.