7
Instruction manual Extraction Motors
Please keep this instruction manual for future reference
WA R N I N G S :
As a result of the new EU65 “Energy label” and EU66 “ Ecodesign” regulations issued by the
European Commission, which came into force on January 1st, 2015, our products have been
adapted to comply with these new requirements. All of the models complying with the energy
label requirements, are equipped with new electronics including a timer device for suction
speeds control, when the air capacity exceeds 650m3/h.
DDMEXT21
and
DDMEXT30
products have a timer control function activated at 4th speed
for 6 minutes, if it is combined with a
DOWNDRAFT
or 5 minutes if it is combined with other
products, such as ceiling hoods, wall hoods and island hoods. Once the above mentioned times
elapse, the motor will switch to 3rd speed automatically.
DDMEXT40
and
DDMEXT25
products have a maximum air capacity higher than 650m3/h
at both 4th and 3rd speed, therefore they will have the following by default timer control
functions:
DDMEXT40 DDMEXT25
with
DOWNDRAFT EM
› 4th speed is time controlled for 6 minutes, after which the product switches to speed 2.
› 3rd speed is time controlled for 7 minutes, after which the product switches to speed 2.
DDMEXT40
and
DDMEXT25
with
CEILING- WALL AND ISLAND HOODS.
› 4th speed is time controlled for 5 minutes, after which the product switches to speed 2.
› 3rd speed is time controlled for 7 minutes, after which the product switches to speed 2.
The energy consumption of the appliance in standby mode is lower than 0.5W.