Caple CR9206 Скачать руководство пользователя страница 9

GAS CONNECTING

2

1

3

4

5

L

N

A

A special valve for routinely turning the gas supply on/off must be

installed between the gas inlet tube to the room and the hob, in

order to cut off the gas supply after cooking in the event of accidents

during cooking. This valve must be easily accessible at all times

and  should  be  closed  during  long  periods  of  no  use.

The gas tube must be routed in such a way that it is not fed through

hot areas and does not come into contact with any hot parts of

the appliance, e.g. the underside of the hob. Tube installation must

be carried out in such a way as to ensure that it runs freely and

that it cannot come into contact with or be bent by any movable

parts in the kitchen, e.g. drawers.

If this is not the case, a special pressure regulator must be fitted

to the gas supply pipe in accordance with the relevant standards.

The cooker must be connected to the gas supply pipe such that

the cooker is not subjected to any kind of stress.

This appliance must be installed by a qualified electrician / competent

person 

gas safe register. 

Safety may be impaired if installation

is    not  carried  out  in  accordance  with  these  instructions.

This appliance shall be installed in accordance whit the regulations

in force and only in a well-ventilated space. Read the instructions

before installing or using this appliance.

IMPORTANT

We recommend to check wether the appliance has been foreseen

for the kind of gas distributed. Conversion for use other gases

must only be undertaken by a qualified person. For information for

use on other gases contact your local Service Centre. The cooker

must  be  installed  by  a  qualified  person,  conforming  to  local

regulations. Failure to install the appliance correctly could invalidate

any manufacturers warranty and lead to prosecution under the

above quoted regulations.

In order to guarantee that the cooker works safely and has a

moderate energy consumption and long service life, you must

ensure that the supply pressure corresponds to the values given

in table D.

Provision for Ventilation

The room containing the cooker should have an air supply in

accordance with local regulations.

Remember that the quantity of air necessary for combustion must

never be less than 2m3/h for each kW of power (see total power

in kW on the appliance data plate).

Gas Safety (Installation & Use) Regulations

It is the law that all gas appliances are installed by competent

persons in accordance with the current edition of the 

Installation

& Use Regulations. 

It is in your interest and that of safety to

ensure compliance with the law.

The appliance must be installed in accordance with All relevant

British Standards (latest editions).

Gas Connection

Prior to installation, ensure that the local distribution conditions

(nature of the gas and gas pressure) and the adjustment conditions

are compatible. The adjustment conditions for this appliance are

stated on the rating plate which can be found on the back cover.

This appliance is not designed to be connected to a combustion

products evacuation device. Particular attention should be given

to  the  relevant  requirements  regarding  ventilation.
Connection to the cooker should be made with connection in

accordance with local regulations.

ELECTRICAL CONNECTION

This appliance must be installed by a qualified person in

accordance with the latest edition of the IEE Regulations and

in compliance with the manufacturer instructions.

Ensure that the voltage is the same as that stated on the rating

plate. The rating plate which can be found on the inside of the

front appliance drawer.

WARNING! THIS APPLIANCE MUST BE EARTHED

The power supply must be fitted with a disconnect switch in which

the distance between contacts permits total disconnection in

accordance with overvoltage category III, as required by installation

regulations.

Be sure that the earth wire green/yellow is not interrupted

by the switch

We recommend that the cooker circuit is rated to 20 amps.

Cable type HO5 RRF  3 X 2.5 mm

2

Connecting the mains cable

Open the mains terminal block cover as shown, unscrew screw

“A” the cable clamp and unscrew (not fully) the screws in the

mains terminal block “L N E” which secure the three wires of the

mains cable. Fit the cable and refit screw “A” the cable clamp.

Allow sufficient cable length for the cooker to be pulled out for

cleaning, but do not let it hang closer than 50mm (2”) to the floor.

The cable can be looped if necessary, but make sure that it is not

kinked or trapped when the cooker is in position.

IMPORTANT

The wires in the mains lead are coloured in accordance with the

following code:

GREEN AND YELLOW......EARTH

BLUE .................................NEUTRAL

BROWN.............................LIVE

9

GB

1/2”

Содержание CR9206

Страница 1: ...Instruction manual for dual fuel range cooker Model code CR9206 AN IV SS Contact Caple on 0844 8003830 or for spare parts www 4caple co uk ...

Страница 2: ......

Страница 3: ... always the kind of problem and the model of your appliance RECCOMANDATIONS AND PRECAUTIONS ATTENTION Before using the appliance do not forget to remove the plastic films protecting some parts of the appliance facia panel parts in stainless steel etc Do not use the appliance as a space heater When the appliance is not in use we recommend to disconnect the current and to close the gas general tap I...

Страница 4: ... up the oven at the maximum temperature for about 30 40 minutes with closed door It is something normal and in case it will occur wait for the smoke to stop before introducing the food into the oven The oven is fitted with a rod shelf for cooking food contained in oven dishes or placed directly on the rod shelf itself a drip tray for cooking sweets biscuits pizzas etc or for collecting juices and ...

Страница 5: ...e on for all the following operations Defrosting with fan The air at ambient temperature is distributed inside the oven for defrosting food very quickly and without proteins adulterations Natural convection Both the lower and upper heating elements operate together This is the traditional cooking very good for roasting joints ideal for biscuits baked apples and crisping food You obtain very good r...

Страница 6: ... how long the button is pressed Setting the time Press any two buttons manual at the same time and or button to set the desired time This deletes any previously set programme The contacts are switched off and the AUTO symbol flashes Manual use By pressing the manual button the relay contacts switch on the AUTO symbol switches off and the saucepan symbol lights up Manual operation can only be enabl...

Страница 7: ...about 10 minutes in hot water with a little detergent After having cleaned and washed them wipe them carefully Make sure that no burner hole is clogged Clean the burners once a week or more frequently if necessary MAKE SURE YOU HAVE ASSEMBLED THE BURNERS IN A RIGHT WAY Sound signal The sound signal starts at the end of a programme or of the minutes counter function and it lasts for 15 minutes To s...

Страница 8: ...hstand high temperatures min 90 C CAUTION The cooker must not be placed on a pedestal If the appliance is to be installed near units leave the minimum gaps specified in the table below The cooker is fitted with 4 legs for an eventual alignment in height with the furniture fig 9 A or 9 B according to the models INSTRUCTIONS DESTINED TO THE USER Fig 9 A Fig 9 B 8 GB min 100 mm min 50 mm min 650 mm m...

Страница 9: ...s than 2m3 h for each kW of power see total power in kW on the appliance data plate Gas Safety Installation Use Regulations It is the law that all gas appliances are installed by competent persons in accordance with the current edition of the Installation Use Regulations It is in your interest and that of safety to ensure compliance with the law The appliance must be installed in accordance with A...

Страница 10: ...128 Triple crown 3300 1300 315 l h 120 Fish 2900 1500 277 l h G P L 30 85 Rapide 3000 750 219 g h BUTANE 28 65 Semi rapide 1750 480 128 g h PROPANE 37 50 Auxiliary 1000 330 73 g h 93 Triple crown 3300 1300 241 g h 85 Fish 2900 1500 211 g h Fig 14 Fig 15 MINIMUM FLOW ADJUSTMENT FOR WORK TOP TAPS In order to adjust the minimum act as follows switch the burner on and turn the knob towards the minimum...

Страница 11: ...he gas entries are not obstructed by grease residuals Assemble everything carefully in the opposite direction check the connection seal by means of soapy water TAPS REPLACEMENT Act as follows switch the appliance off and close the general tap open the work top and disassemble also the control panel as described on the previous paragraph Unscrew screw nut D of the gas tube supplying the burner Unsc...

Страница 12: ...eep the cooker clean as a build up of grease or fat from cooking can cause a fire Do always allow the cooker to cool before cleaning Do always follow the basic principles of food handling and hygiene to prevent the possibility of bacterial growth Do always keep ventilation slots clear of obstructions Do always turn off the electricity before cleaning or replacing an oven lamp Do always use a CORGI...