INSTRUCTIONS FOR THE INSTALLER

Gas connection

Make sure that the appliance is adjusted for 

the gas type available (see the label under the 

appliance). Follow the instructions indicated in the 

chapter “gas transformations and adjustments” for 

the possible adaptation to different gases.

The appliance must be connected to the gas 

system by means of stiff metal pipes or flexible 

steel pipes having continuous walls, in compliance 

with the regulations in force.

Some models are equipped with both cylindrical 

A and conical B connectors for gas supply (fig. 7).

Please select the type which is correct for the 

supply concerned.

The connection must not stress the gas ramp.

 

Once the installation is over, check the 

connection seal with a soapy solution. 

Electric connection

The connection to the electric grid must be carried 

out by qualified personnel and in conformity with 

the regulations in force.

The voltage of the electric system must correspond 

to the value indicated in the label under the 

appliance. Make sure that the electric system is 

provided with an effective ground connction in 

compliance with the regulations and provisions of 

the law. 

Grounding is compulsory

This device must be at a suitable opening distance 

from the contacts in order to allow the entire 

disconnection in case of overvoltage category 

III

in accordance with installation rules.

GAS TRANSFORMATIONS AND ADJUSTMENTS

Replacing the nozzles

If the equipment is adjusted for a type of gas that is 

different from the one available, it is necessary to 

replace the burner nozzles.

The choice of the nozzles to replace must be 

made according to the table of the “technical 

characteristics” as enclosed.

Act as follows:

 -Remove the racks and burners.

 -By means of a straight spanner L, unscrew 

the nozzle U (fig.8) and substitute it with the 

corresponding one.

 -Tighten the nozzle strongly.

Adjusting the burners

The lowest flame point must always be properly 

adjusted and the flame must remain on even if 

there is an abrupt shift from the maximum to the 

minimum position.

If this is not so, it is necessary to adjust the lowest 

flame point as follows:

 -start the burner up

 -turn the tap up to the minimum position (small 

flame)

 -remove the knob from the tap rod

 -introduce a flat-tip screwdriver in the hole F of 

the tap (fig.9) and turn the by-pass screw up to a 

proper adjustment of the lowest flame point.

As regards G30 gas burners, the by-pass screw 

must be tightened completely.

MAINTENANCE

Replacing the power supply cable

If the power supply cable should be replaced, 

it is necessary to use a cable with a section of 

3x0.75mm

2

, type H05VV-F or H05RR-F, complying 

with the regulations in force.

The connection to the terminal board must be 

effected as shown in fig.10:

brown cable L  

      (phase)

blue cable N  

      (neutral)

green-yellow cable       (ground)

Содержание C993G

Страница 1: ...GB Instruction manual for gas hobs Model code C993G Contact Caple on 0844 800 3830 or for spare parts www 4caple co uk ...

Страница 2: ... with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction cencerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance While the appliance is running watch the children and make sure they neither stay near the equipment ...

Страница 3: ...If the flame should blow out accidentally the safety valve will automatically stop the gas supply after a few seconds To restore operation set the knob to the lighting point large flame fig 1 and press While cooking with fat or oil pay the utmost attention as these substances can catch fire when overheated Do not use sprays near the appliance in operation Do not place unstable or deformed pots on ...

Страница 4: ...ven without forced cooling ventilation proper air vents must be installed to guarantee an adequate ventilation with the lower air entering with a cross section of at least 200cm2 and the higher air exiting with a cross section of at least 60 cm2 Fastening the top Every cook top is equipped with a special washer A set of hooks is also supplied for mounting the cook top Depending on the type of moun...

Страница 5: ...vervoltage category III in accordance with installation rules GAS TRANSFORMATIONS AND ADJUSTMENTS Replacing the nozzles If the equipment is adjusted for a type of gas that is different from the one available it is necessary to replace the burner nozzles The choice of the nozzles to replace must be made according to the table of the technical characteristics as enclosed Act as follows Remove the ra...

Страница 6: ...6 CLOSED Maximum Minimum 1 9 10 F 5 6 2 3 4 7 8 ...

Страница 7: ...7 1 Rapid burner 3000 W 2 Semi rapid burner 1750 W 3 Control knob for burner C993G 1 2 3 ...

Страница 8: ...its useful life Failure to do so may result in a fine as provided for by laws governing waste disposal Differential collection of waste products for eventual recycling treatment and environmentally friendly disposal helps reduce possible negative effects on the environment and health and also enables the materials making up the product to be recycled For more detailed information on the available ...

Отзывы: