Instruction manual C871GBK
Please keep this instruction manual for future reference
18
As the colours of the wires in the mains lead may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows: Connect the Green & Yellow wire to
terminal marked ‘E’or
●
The fuse and electrical system can withstand the load required by the appliance;
●
That the electrical supply system is equipped with an efficient earth hook-up according to the norms and
regulations prescribed by law;
●
That the plug or switch are easily accessible.
Important:
the wires in the mains lead are coloured in accordance with the following code:
Green & Yellow
- Earth
Blue
- Neutral
Brown
- Live
As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows: Connect the Green & Yellow wire to terminal marked "E"
or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked "L" or coloured Red.
Connect the Blue wire to the terminal marked "N" or coloured Black.
Adapting the hob for Different Types of Gas
Table1
Burners and Injector Specifications
G20 (UK)
G25
G25.1
G27
G2.350
G30 (UK)
Burner
Thermal
power
(kW)
Injector
1/100
(mm)
Therma
l power
(kW)
Inject
or
1/100
(mm)
Thermal
power
(kW)
Injector
1/100
(mm)
Thermal
power
(kW)
Injector
1/100
(mm)
Thermal
power
(kW)
Injector
1/100
(mm)
Thermal
power
(kW)
Injector
1/100
(mm)
Injector
1/100
(mm)
Injector
1/100
(mm)
Auxiliary
0.90
69
0.90
69
0.90
69
0.90
75
0.90
96
0.90
50
44
43
Semi rapid
1.88
97
1.88
97
1.88
97
1.88
106
1.88
131
1.88
68
64
60
Triple Ring
3.00
131
3.00
131
3.00
131
3.00
136
3.00
165
3.00
86
82
75
Supply
pressures
20mbar
25mbar
25mbar
20mbar
13mbar
30
mbar
36
mbar
50
mbar
At 15°C and 1013 mbar-dry gas
P.C.I.G20 37.78 MJ/m³ P.C.I.G25.1 32.51 MJ/m³
P.C.I.G25 32.49 MJ/m³ P.C.I.G27 30.98 MJ/m³
P.C.I.G2.350 27.20MJ/ m³ P.C.I.G30 49.47MJ/Kg
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked “L” or coloured Red.
Connect the Blue wire to the terminal marked “N” or coloured Black.
BURNERS AND INJECTOR SPECIFICATIONS
G20
G25
G25.1
G27
G2.350
G30
Burner
Thermal
power
(kW)
Injector
1/100
(mm)
Thermal
power
kW
Injector
1/100
(mm)
Thermal
power
kW
Injector
1/100
(mm)
Thermal
power
kW
Injector
1/100
(mm)
Thermal
power
kW
Injector
1/100
(mm)
Thermal
power
kW
Injector
1/100
(mm)
Injector
1/100
(mm)
Injector
1/100
(mm)
Auxiliary
0.90
69
0.90
69
0.90
69
0.90
75
0.90
96
0.90
50
44
43
Semi rapid
1.88
97
1.88
97
1.88
97
1.88
106
1.88
131
1.88
68
64
60
Rapid
2.40
110
2.40
110
2.40
110
2.40
121
2.40
147
2.40
78
72
68
Triple Ring
3.00
131
3.00
131
3.00
131
3.00
136
3.00
165
3.00
86
82
75
Supply
pressures
20mbar
25mbar
25mbar
20mbar
13mbar
30
mbar
36
mbar
50
mbar
Table1
Burners and Injector Specifications
C871GBK - Instruction Manual.indd 18
12/04/2019 13:57