background image

Cod. 1101809

ß2

CAPLE “Built-in” Service

Should you require service at any time,
please contact the Caple Helpline on
0870 241 1142.

Caple have a nationwide service net-
work of engineers who will respond
quickly to your call.

YOUR GUARANTEE

CAPLE guarantees all parts of this product for one year from the date of pur-

chase. During that time, should it become necessary CAPLE engineers will

replace or repair all defective parts free of charge, except for parts subject to

fair wear and tear, such as lightbulbs.

Parts and the engineers labour costs are chargeable after the first 12 months.

To qualify for benefits under the guarantee, you must be able to provide proof
of date of purchase and the appliance must have been supplied, installed and

used for domestic purposes only in accordance with CAPLE instructions.

Consequential losses and accidental damage to the product are not covered

by the guarantee.

This guarantee does not affect your statutory or common law rights.

CAPLE cannot be responsible for the results of using this appliance for any

other purposes other than those described in these instructions.

Always replace spare parts with gen-
uine  Caple spares. These are available
from authorised Caple Service
Centres 
or by mail order from our
National Service Stores, simply tele-
phone 0870 241 1142.
When ordering parts always quote the
model number and serial number of
your appliance.

Содержание C761G

Страница 1: ...Instruction Manual GB Gas Hob Model C 761 G ...

Страница 2: ...tions and a cleaning guide as well as other important facts about your CAPLE Gas Hob If treated with care your CAPLE Gas Hob should give you years of trouble free cooking For Spare Parts Technical Advice or Product Service call the CAPLE HELPLINE on 0870 241 1142 Answerphone outside office hours Contents The CE marking confirms that the appliance conforms to the following EU directives safety requ...

Страница 3: ... or coloured Green 2 The wire which is coloured blue must be connected to the terminal marked N Neutral or coloured Black 3 The wire which is coloured brown must be connected to the terminal marked L Live or coloured Red FUSE DOUBLE POLE SWITCHED FUSED SPUR OUTLET USE A 3 AMP FUSE ON Fig 1 WARNING ELECTRICITY CAN BE EXTREMELY DANGEROUS THIS APPLIANCE MUST BE EARTH ED Installation Requirements Tech...

Страница 4: ...ith Natural Gas at 20 mbar After connecting to the mains check that the couplings are correctly sealed using soapy solution but never a naked flame BURNERS Auxiliary A 1 00 0 32 40 65 Semi rapid SR 1 60 0 39 43 85 Rapid R2 2 40 0 58 55 110 Rapid R1 3 05 0 67 60 115 15 Double ring DR 3 20 0 77 62 125 Nominal input kW Reduced input kW By pass 1 100 mm Ø injector 1 100 mm Natural Gas 20 mbar Injector...

Страница 5: ...ets above the hob This hob must not be installed above refrigeration products 450 mm COOKER HOOD 750 mm 900 mm cabinet only without cooker hood Fig 2 Ventilation All rooms require a window which can be opened or equivalent while some rooms require a permanent vent in addition to a window This unit must not be used in a room with less than 5 m3 Room Volume Air vent necessary effective area 5 m3 100...

Страница 6: ...ated in figure 5 4 Tighten carefully 5 Using a sharp tool trim any excess gasket which protrudes from the edge of the hob 6 Assemble the three piece burners Take care to properly locate the assembled burner on the burner base fig 6 NOTE A partition between the base of the hob and the cupboard below should be fitted 100 mm below the worktop if the cupboard is to be used for storage Never place peri...

Страница 7: ...7 Adhesive side Fig 5 Fig 4 Fig 6 20 mm min 40 mm max B C A ...

Страница 8: ...kW 2 Rapid burner R1 3 05 kW 3 Semirapid burner SR 1 60 kW 4 Rapid burner R2 2 40 kW 5 Double ring burner 3 20 kW CONTROLS DESCRIPTION 10 Electric lighter button 11 Burner control knob 1 A 12 Burner control knob 2 R1 13 Burner control knob 5 DR 14 Burner control knob 3 SR 15 Burner control knob 4 R2 ...

Страница 9: ...allows the gas to reach the burner push the knob and turn it to the left To close it turn the knob to the right until the safety device releases The maximum flow is used for boiling while the slow flow is used for simmering food or keeping it on the boil All the operating positions must be chosen between the maximum and minimum positions never between the maximum and off positions Lighting the bur...

Страница 10: ...ck the state of the connection hose to the bottle or to the gas distribution duct occasionally it must be in perfect condition and must be replaced if there are any defects or depending on the date of use case of a connection where the hose can be inspected Regular lubrication of the taps must be performed only by qualified staff If there are operating problems contact the After Sales Service Cent...

Страница 11: ...referably clean with a cloth Stainless steel Clean with a suitable product Always dry carefully Black burners oxi black coating They can be removed and washed only with soapy water Detergents can be used but must not be abrasive or corrosive Do not use abrasive sponges or pads Do not put in dishwasher After each cleaning make sure that the burner caps as well as the burners have been well wiped of...

Страница 12: ... for benefits under the guarantee you must be able to provide proof of date of purchase and the appliance must have been supplied installed and used for domestic purposes only in accordance with CAPLE instructions Consequential losses and accidental damage to the product are not covered by the guarantee This guarantee does not affect your statutory or common law rights CAPLE cannot be responsible ...