V A LV E A D J U S T M E N T
Valve adjustment should be done with the control knob set at the reduced rate (small flame)
position.
Remove the knob, and adjust the flame with a small screwdriver
Checking the adjusted flame: heat the burner at full open position for 10 minutes. Then turn the
knob into the minimum setting. The flame should not extinguish nor move to the injector. If it goes
off or moves over to the injector, readjust the valves.
N O T E :
It is up to the user to request converting the appliance to another gas type if so required by the
local conditions at a licensed gas fitter/service.
。
。