Electrical connection
Make certain the nominal a.c. power supply voltage corresponds to that indicated on the
identification data plate. The appliance must be connected to the supply by way of an isolating
switch with minimum contact separation of 3 mm. Suitable isolating components include automatic
breakers, fuses and relays.
The oven must be connected to an efficient earth system, as prescribed by national and/or local
statutory regulations.
The cable must be connected as prescribed by statutory regulations and respond to the
specifications indicated on the Technical Data page.
The terminal box is located at the rear of the appliance. If a new cable is fitted, route it through
the clamp and make the connections as shown in the diagram. The earth wire must be cut longer
than the other wires so that it will be the last to break off in the event of the cable being tugged.
Having made the connection, tighten the cable clamp and close the cover of the box.
CONNECTION DIAGRAM
CABLE TYPES AND SECTIONS
H05RR-F
230V~ 3 x 2,5 mm
2
230V 3 4 x 1,5 mm
2
400V 2N~ 4 x 1,5 mm
2
400V 3N~ 5 x 1,5 mm
2
Содержание C3370