3
C125F Built-under Freezer instructions.doc
ENVIRONMENTAL INFORMATION
This equipment was designed and built with the maximum respect for the environment.
To guarantee the same scrupulosity when it's disposed of (given the presence of pollutant or
inflammable materials, e.g. lubricant in the compressor), never abandon the equipment
outside. Contact the local authority responsible for collection and disposal.
Don't throw the packaging material from your equipment in the rubbish but sort the various
materials (e.g. polystyrene, cardboard, plastic bags) as required by local waste disposal
authorities in pursuance of current legislation.
This equipment does not contain CFCs (the cooling circuit contains R134a) or HFC’s (the
cooling circuit contains R600a - ISOBUTANE).
To check what gas is used, see the technical data plate on the equipment.
For equipment with ISOBUTANE (R600a)
Isobutene is a natural gas that doesn't affect the environment, but it is inflammable.
It is therefore indispensable to check that the cooling circuit tubing is not damaged before
connecting the equipment to the mains.
•
For every 8 g of cooling fluid, the installation location must have a minimum volume of 1
cubic meter. The amount of cooling fluid in the appliance is indicated on the technical
data plate inside the freezer.
•
Leakage of cooling fluid: avoid naked flames or other sources of ignition at the seat of
the leakage.
INSTALLATION
In order to avoid damage to persons or property, the equipment should be installed by two
persons. In the event of damage to the equipment during transport, immediately inform the
supplier before proceeding to installation. The equipment must be placed in a dry, well
ventilated position.
The equipment must be installed on a flat, stable surface, using the adjustable feet if
necessary and following the instructions provided inside the product.
In fitting the equipment inside the unit make sure you don't squash the power cable.
Air inflow to and outflow from the equipment must be ensured by means of an aperture in
the skirting board and a vertical slit in the rear of the unit.
Minimum transverse section of aperture in skirting board and slit: 250cm
2
.
Ambient temperature has a considerable influence on energy consumption, so the
equipment should not be exposed to direct sunlight or placed by heat sources such as
radiators, heaters, cookers, etc. If necessary install insulation paneling against the sides of
the unit.
Check the climate classification on the technical data plate inside the equipment, on the left
hand side.
"SN" (operates at ambient temperatures between) +10° C and +32° C
"N" (operates at ambient temperatures between) +16° C and +32° C
"ST" (operates at ambient temperatures between) +16° C and +38° C
"N" (operates at ambient temperatures between) +18° C and +43° C