10
TABLE FOR THE CHOICE OF THE INJECTORS
Cat:
II
2H3+
GB
BURNERS
REGULATION OF THE MINIMUM FLAME
(FOR FITTERS USE ONLY)
NOTE: The flame has been regulated for use with Natural Gas, however, when
converting to L.P.G. the flame may need adjusting.
Turn the thermostat to the maximum setting and pre-heat the oven, without grill pan and
base plate, for approximately ten minutes, turn the control to the 1/2 position.
Remove the knob and adjust the thermostat by-pass screw (Fig. 3.4) to obtain a short
sharp stable flame. (The flame is visible through the holes in the oven base).
Check that moving the control knob from the maximum flame position to the 1/2 setting,
or rapidly opening and closing the oven door does not make the flame go out.
G 30
- 28-30 mbar
G 20
G 31
- 37 mbar
20 mbar
OVEN
3,000
0,650
40
83
15 *
125
4 *
Nominal
Power
[kW]
Reduced
Power
[kW]
Ring opening
[mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Ring opening
[mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
adjustable
*