6
If, having followed these instructions carefully, your cooker hood fails to work properly please carry out the following
checks.
Symptom CHECK
The cooker hood will not start
Check the hood is connected to the electricity supply.
Check that the fan speed control is set to 1, 2 or 3.
The cooker hood is not working
effectively
The fan speed is set high enough for the task.
The grease filter is clean.
The kitchen is adequately vented to allow the entry of fresh air.
If set up for recirculation, check that the charcoal filter is still
effective.
If set up for extraction, check that the ducting and outlets are
not blocked.
The cooker hood has switched off
during operation.
The safety cut-out device has been tripped.
Turn off the hob and then wait for the device to reset.
•
If after all these check s, the problem persist s, telephone the
Caple Service Centre 08
44 800 3830
,
quoting the model and serial number.
•
Please note that it will be necessary to provide proof of purchase for any in-guarantee service calls.
•
In-guarantee customers should ensure that the above checks have been made as the engineer
will make a charge if the fault is not a mechanical or electrical breakdown.
Electrical Requirements
Any permanent electrical installation must comply with the latest I.E.E. Regulations. For your own safety this should
be undertaken by a suitably qualified electr ician who is on the roll of the National Inspection Council for Electrical
Installation Contracting (NICEIC).
THIS PRODUCT MUST BE CORRECTLY EARTHED.
The connection must be made as follows: -
o
Brown
=
Live
o
Blue
=
neutral
o
Yellow/Green =
Earth
Electrical Connection
Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate
inside the cooker hood.
This appliance is fitted with a 13 amp plug for connection to a suitable outlet which should be positioned for easy
access.
If it is intended to connect directly to the electricity supply, the plug should be removed and the 3 core mains cable
and should be permanently connected to the electricity supply via an approved Switched Fused Spur outlet meeting
BS1363 Part 4, fitted with a 3 Amp fuse.
This appliance conforms to BS 800: 1988 and EEC Directive No. 78 308 regarding suppression of radio and television
interference.
TROUBLESHOOTING
ELECTRICAL CONNECTIONS