natural gas requirements:

Verify the type of gas to be used, either LP (propane), or Natural gas, 
and make sure the marking on the appliance rating plate agrees with 
that of the supply.  The rating plate is located on the outside back wall of 
the grill.  

NEVER connect an unregulated gas line to 

the appliance!

An installer supplied gas shut-off valve must be installed in an easily 
accessible location.  All installer-supplied parts must conform to local 
codes, or in the absence of local codes, with the National Electrical 
Code, ANSI/NFPA 70-1990, and the National Fuel gas Code, ANSI 
Z223.1-1988. 

All pipe sealants must be an approved type and resistant to the actions 
of LP gases.  Never use pipe sealant on flare fittings.  All gas 
connections should be made by a qualified technician and in 
accordance with local codes and ordinances.  In the absence of local 
codes, the installation must comply with the National Fuel Gas Code 
ANSI Z223.1-1988.  Gas conversion kits are available from the factory.  
When ordering gas conversion kits, please have the model # and gas 
type (natural or LP) available from your grill.

TOTAL GAS CONSUMPTION  = 30,000 BTU/HR

The appliance and its individual shut-off valve must be disconnected 
from the gas supply piping system during any pressure testing of that 
system at test pressures in excess of 1/2 PSIG (3.5 kPa).  The 
appliance must be isolated from the gas supply piping system by closing 
its individual manual shut-off valve during any pressure testing of the 
gas supply piping system at test pressures equal to or less than 1/2 
PSIG (3.5 kPa).  The installation of this appliance must conform with 
local codes or, in the absence of local codes, with the National Fuel Gas 
Code, ANSI Z223. 1a-1988.  Installation in Canada must be in 
accordance with the standard Can 1-b149.1 and/or .2 (installation code 
for gas burning appliances and equipment) and local codes. 

NATURAL GAS HOOKUP:

Connection: 1/2” NPT male. Operating Pressure: 4.0” W.C.
Supply Pressure: 5” to 14” water column.  If in excess of 14” W.C. 
a step down regulator is required.  Check with your local gas utility 
company or with local codes for instructions on installing gas supply 
lines.  Be sure to check on type and size or run, and how deep to bury 
the line.  If the gas line is too small, the grill will not function properly.  
Any joint sealant used must be an approved type and be resistive 
to the actions of LP gases. 

TO HOOK-UP THE FITTINGS SUPPLIED WITH THE SIDE BURNER:

Use threading compound on male threads only. Use second pipe 
wrench to hold the grill inlet pipe to avoid shifting any internal gas lines 
of the grill.  Ensure that the regulator arrow points in the direction of gas 
flow towards the unit, away from the supply.  

Do not forget to place the installer supplied gas valve in an 
accessible location. 

performance fact!

5

Содержание Performance Series PSQSB2000

Страница 1: ...U S E A N D C A R E G U I D E P E R F O R M A N C E S E R I E S S I D E B U R N E R S THE POWER OF PERFORMANCE TM...

Страница 2: ...s NAT LP 5 6 Leak Testing 7 Built In Clearances 8 Replacing Regulators and Hose 9 Lighting Instructions 10 Care and Cleaning 11 Troubleshooting 12 Installer s Final Checklist 13 We re here for you 14...

Страница 3: ...de ourselves on superior customer service and work harder to respond to your needs quickly and effectively Our Customer Service representatives are here to assist you and are just a phone call away Yo...

Страница 4: ...Do not try lighting this appliance without reading the Lighting Instructions section in this manual Improper installation adjustment alteration service or maintenance can cause property damage injury...

Страница 5: ...burner NEVER let clothing pot holders or other flammable materials come into contact with or come too close to any grate burner or hot surface until it has cooled Fabric may ignite and result in pers...

Страница 6: ...the gas supply shut off valve is located so that you know where to shut off the gas to the grill IF YOU SMELL GAS your installer has not done a proper job of checking for leaks If the connections are...

Страница 7: ...from open edges of the unit to avoid burns associated with unintentional spillovers Hold the handle of the pan to prevent movements of the utensil when turning or stirring food For proper lighting and...

Страница 8: ...s in excess of 1 2 PSIG 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping sy...

Страница 9: ...tem to purge before attempting to light the burners NOTE Side Burner uses the LP regulator from adjoining grill LP TANK REQUIREMENTS A dented or rusty LP tank may be hazardous and should be checked by...

Страница 10: ...o the unit They are located at the bottom left and right hand corners of the front fascia Using a screwdriver remove the screws Lastly gently pull the panel downward and out making sure that you do no...

Страница 11: ...t The counter should also be level 4 x 4 opening for manifold intake pipe A B C A width 11 1 8 B height 8 3 4 C depth 24 3 4 KEY LOCATION When determining a suitable location take into account concern...

Страница 12: ...LP is there gas in the tank Always keep your face and body as far away as possible from the Side Burner when lighting DO NOT leave the side burner unattended while cooking KEEP a spray bottle of soap...

Страница 13: ...iron for maximum durability The side burner cover protects the Side Burners from dust and debris and also acts as a work surface When using the grill burners with the Side Burner cover in place be ca...

Страница 14: ...ust are allowed to collect over time the presence of these materials can seriously jeopardize burner performance It will be necessary to clean out the burner ports using a thin wire needle or straight...

Страница 15: ...ld see a spark jump from the tip of the ignition when the ignition is pushed If there is no spark when ignition button is pushed check the battery condition Battery condition should be checked at leas...

Страница 16: ...l or 10 W C LP gas All Internal Packaging Removed Manual Shut Off Valve Installed and Accessible Knobs Turn Freely and Bezels Centered Unit Tested and Free of Leaks Each Burner Lights Individually Ign...

Страница 17: ...prings CA 90670 USA Fax us at 562 903 1167 Email us at customerservice capital cooking com FOR ________________________________________________________________________ MODEL __________________________...

Страница 18: ...ns or liability in connection with the sale of this appliance WILL NOT PAY FOR Installation or start up Shipping damage Service by an unauthorized agency Damage or repairs due to service performed by...

Отзывы: