Downdraught: Wind can blow down a chimney if there is something higher nearby such as a 
tree, hill or   

high building. Fitting an anti-downdraught cowl to the chimney top can cure 

this. Types which cannot be   swept through are not recommended. 

 

Poor chimney draught: Chimney draught in use MUST be at least 12Pa. 

Chimney Fire:

 

In the rare event of deposits inside the chimney igniting (roaring sound + dense 

smoke and sparks from the chimney) immediately close the door, shut all air controls, evacuate 
the premises and call the fire brigade. Prevent fires by using very dry fuel and having your 
chimney swept regularly. 

Fume Emission 

Warning Note 

 

 

 

Properly installed, operated and maintained this stove will not emit fumes into the dwelling.  

Occasional fumes from de ashing and re fuelling may occur.  However, persistent fume emission is 
potentially dangerous and must not be tolerated. If fume emission does persist, then the following 
immediate action should be taken: 

 

(a)

 

Open doors and windows to ventilate the room and then leave the premises.

 

(b)

 

Let the fire go out.

 

(c)

 

Check for flue or chimney blockage and clean if required.

 

(d)

 

Do not attempt to relight the fire until the cause of the fume emission has been identified and  
 

corrected.  If necessary seek expert advice.

 

The most common cause of fume emission is flueway or chimney blockage. For your own safety 

these must be kept clean at all times.

 

Maintenance 

Monthly: Check that the flue is clear and unblocked, and that the door seals are sound. 

Annually: Sweep the chimney, the entire length of the chimney from stove to outlet should be 

swept. New Parts: Your stove has been extensively tested for safety – please don’t try to modify it 
and always obtain genuine spare parts from your stove shop or the manufacturer. 

Surface Finish: Wipe the stove body with a slightly damp cloth when cool. Never use aerosol 

spray or wax near the hot fire – they can ignite. Painted steel parts can be refurbished using 
special stove spray paint. Your stove generates very high temperatures; eventually the internal 
parts will require replacement. 

Our designs are registered at the UK patent office and protected by Copyright 

©

 and UK Design Right. Certain parts 

are UK Patent Applied For. This document issued March 2018. We are always striving to improve these products and 

may change their specification without notice.

 

Содержание PANAMERA

Страница 1: ...P A N A M E R A S T O V E I N S T R U C T I O N S PLEASE READ THESE INSTRUCTIONS AND USE ONLY THE RECOMMENDED FUELS ...

Страница 2: ...EGUARD SAFETY CHIMNEY STOVE CLEARANCES FLUE LINER FIREPLACE AIR SUPPLY EXTRACTOR FANS 6 7 FITTING 8 9 LIVING WITH YOUR STOVE OPERATING TOOLS LIGHTING FILLING DAMPERS CONTROL EMPTYING ASHES EXTENDED BURNING CO ALARM AEROSOLS CLEAN WINDOWS DOOR SUMMER SHUT DOWN FUELS SMOKE CONTROL WOOD ANTHRACITE BRIQUETTES 10 12 SPARE PARTS 13 ...

Страница 3: ...Page 3 of 18 TROUBLESHOOTING 14 MAINTENANCE 15 REDUCING CARBON EMISSIONS IN THE UK ...

Страница 4: ...ly ignited Open the door and use a poker to lay the kindling across the width of the grate It is best to keep the fuel towards the back of the grate during these early stages Place a small kiln dried log less than 15 moisture on top of the kindling and close the door Wet wood will cause the stove window to blacken Do not cover the tertiary air holes the small holes located at the rear of the fireb...

Страница 5: ... OR TRADEMARK 2 MODEL IDENTIFIER PANAMERA VEGA PANAMERA 3 ENERGY CLASS A 4 DIRECT HEAT OUTPUT 4 8KW 5 INDIRECT HEAT OUTPUT N A 6 ENERGY EFFICIENCY INDEX 106 3 7 ENERGY EFFICIENCY AT NOMINAL HEAT OUTPUT 79 5 8 SPECIFIC PRECAUTIONS SEE MANUAL Fuel Wood Beech Mineral Fuel Anthracite Test Standard EN13229 EN13229 Test Cycle 1 06kg over 0 68hrs 0 60kg over 1 01hrs Settings Primary 0 2nd 100 Primary 100...

Страница 6: ...control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area In England appliances are exempted ...

Страница 7: ... SAFETY Installers must work accordingly under the Health and Safety at Work Act 1974 This appliance becomes extremely hot and can produce poisonous gases A fire guard should be used if children or the infirm are present The installer is required to exactly follow these instructions and to completely comply with all relevant local national and international standards Installing a stove is a contro...

Страница 8: ...with the throat plate removed fit hatches for cleaning access if needed Stove clearances to non combustibles 125mm Flue Liner It is recommended to fit with a 150mm liner for best performance however If only dry wood or anthracite is to be burnt on this appliance then it is possible to fit with a 125mm liner IMPORTANT if you intend to burn unauthorised fuels on this appliance then a 150mm liner mus...

Страница 9: ...nty The effect of ceiling fans should be checked during the tests Extra ventilation should be supplied if tests show that this is necessary FITTING Before beginning the installation please refer to the British Standard BS 8303 Code of Practice for installation of domestic heating and cooking appliances burning solid mineral fuel and the current issues of British Standards BS EN 15287 1 2007 design...

Страница 10: ...imney using a short up to about 500mm length of uninsulated pipe in several ways four of which are shown below Whichever method is used it is imperative that 1 The route for gases from the stove to the chimney terminal is completely air tight even the tiniest gap or crack can spoil the updraught Seal all joins with fireproof cement and or heatproof rope 2 It is possible to sweep the entire length ...

Страница 11: ...The Flue Collar should be attached to the stove top as per the illustration LIVING WITH YOUR STOVE Every fuel chimney and condition of use is different Only experience will show which are the best settings for you Operating Tools Parts become very hot while the stove is running so should not be touched with bare hands Special operating tools or a glove are is provided for operation of the hot stov...

Страница 12: ... intended for quick heat up intermittent use While well capable of lasting for many hours they are not designed for overnight burning For best extended burning results allow the fire to burn down to a low hot firebed and fully fill with a hard fuel such as anthracite c30mm size is best and set the air controls to low CO Alarm Your installer should have fitted a CO alarm in the same room as the app...

Страница 13: ...t performance and always for low smoke emission Split logs lengthways for drying Use logs no bigger than about 100mm x 250mm Ensure logs are absolutely dry less than 15 moisture Fill the stove criss cross so air can circulate between logs Fill little often Always have the airwash control at least a little open When first lighting or reviving a fire from embers use only very small thin dry sticks N...

Страница 14: ...ick F Base Brick Pair 1 Stove Body 2 Removable Latch Pin 3 Stainless Steel Grate 4 Top Plate 5 Flue Collar 6 Log Retaining Bar 7 Ash Bin 8 Rear Baffle 9 Flue Blanking Plate 10 Vermiculite Retaining Bar 11 Vermiculite Brick Set 12 Stove Door 13 Fixing Bolts 14 Fixing Bolts 15 Fixing Bolts 16 Fixing Bolts 17 Handle Assembly ...

Страница 15: ...Page 15 of 18 ...

Страница 16: ...Firing It is possible to leave the fire too long with the controls set too high leading to over firing seen as glowing metal parts excessive chimney temperature and risk of parts failing or chimney fires Always set controls to the lowest practical setting A chimney thermometer from your local stove shop can help Smoke Coming Into Room Fumes are poisonous smoke emission must never be tolerated caus...

Страница 17: ...eck for flue or chimney blockage and clean if required d Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected If necessary seek expert advice The most common cause of fume emission is flueway or chimney blockage For your own safety these must be kept clean at all times Maintenance Monthly Check that the flue is clear and unblocked and that the d...

Страница 18: ...Tel 01462 813138 Fax 0800 980 4847 Email sales capitalfireplaces co uk Website www capitalfireplaces co uk For North of England sales please contact Percy Doughty Co Ltd Imperial Point Express Trading Estate Stone Hill Road Farnworth BL4 9TN Tel 01204 868550 Fax 01204 868551 Email sales percydoughty com Website www percydoughty com ...

Отзывы: