LIFETIME WARRANTY
(On select models only)
To avail the lifetime warranty you need to register online within 90 days of your purchase.
To register online you need to do the following:
Log on to glen website
www.capellaindia.com
Click on lifetime warranty, it will open a window there you need to feed the Lifetime Warranty unique ID,
model number and serial number of the chimney hood.
For LTW unique ID and serial number you need to open the chimney hood. You will find two labels one for
LTW unique ID and other for serial number.
(Never ever remove the labels otherwise the warranty becomes void)
.
If all your information is correct and matches with our record another window will open wherein you will
need to fill the personal details like name & address etc.
Once you complete the information and press submit a confirmation number will be given for future
reference. Also one confirmation mail with all the details will be sent to your email id. You are requested to
take a printout of the same and keep it safe. In case of any repair in future you will need to show this mail to
the service engineer to avail the lifetime warranty.
Note
: The offer lapses if not registered with in 90 days of date of purchase.
The chimney should be used as per the directions given in the user's guide. Defects caused by improper
or reckless use are not covered.
Any damages due to the use of abrasive chemicals, or usage in extremely adverse atmosphere, i.e.
abnormally corrosive / alkaline / acidic is not covered under warranty.
The warranty will not cover Chimneys used for commercial purposes.
The chimney should have been serviced and cleaned at regular intervals at-least once in two months by
a Glen Authorised Service Centre failure to comply with this will render this warranty void. The cost of
any such service will be borne by the customer.
No installation / modification / alteration / service of any nature is made in the chimney by unauthorised
persons. The Installation Charges are to be borne by the customer.
Only the parts covered under LTW will be replaced free. The labour charges for the replacement of under
warranty parts will be borne by the customer. The visit charges (within municipal area only) of Rs. 250/-
(subject to change from time to time) will be charged extra.
This chimney has been designed to last a long time and depending on the up-keep & maintenance by the
customer the Chimney may last a long time but for the purpose of Life Time Warranty the Life of the
Chimney will be taken as 7 years from the date of Purchase of the Chimney.
The warranty is not valid for any damages arising due to erratic power supply.
The warranty is not valid in case chimney is used on Inverter or Generator.
The Life Time Warranty is offered on the following conditions:
Switch on the chimney 5 minutes before you start cooking. Before
using the chimney please ensure that all plastic films on the filter and
stainless steel body are removed.
The push button/slider control have three speed settings. Kindly
choose the speed as per your requirement.
Two lamps are provided in the chimney to enable proper lighting up of the cooking area. The light works
independently of whether the fan is switched on or off, as it is provided with separate on/off switch.
Light
INSTALLATION
The chimney must be mounted over the center of the cooking area. The minimum
distance between the cooktop and the bottom of the chimney must be 750 mm.
If there is no outer waste-pipe for the exhaust, an air outlet with a diameter of
130 mm must be made through the wall. The exhaust pipe from the top of the
chimney, should be connected to the exhaust.
Fastening the chimney to the wall
Mark the position of the holes on the wall. Before drilling make sure that no
wiring and tube will be damaged. Drill two fastening holes, drive in the wall
plugs and screw in the screw until their heads are about 6 mm from wall.
Place the chimney to the wall in order to check that it seats properly. Then mark the position of the two
holes. Take it off from the wall now, drill the holes and fit the plugs.
Place the hood once again to the wall, and introduce the screws from the inside of the appliance.
The product can be used in re-circulation or the exhaust mode. It is however
recommended that wherever possible it should be used in exhaust mode for
best results.
Your chimney is provided with option of ducting from back or top depending on
the site. Before installation in case of air exhaust from back remove the cover
from back and fix it to top air outlet. now take the spigot and fit in the back air
outlet.
750 mm
750 mm
MAINTENANCE
When performing maintenance operations, disconnect the plug from the
socket.
The efficiency of the chimney depends on the condition of the filters.
The filters should be washed as often as possible but at least once in10 to 15
days in normal operating conditions.
The baffle & aluminium filters can be removed easily by unlocking.
Dip the filter for 10-15 minutes into a boiling hot soap solution and then wash in
running water. Dry and reinstall the filter.
The chimney surface should be cleaned with a damp cloth. No abrasive chemicals should be used.
Frequent cleaning of filter is very important to avoid danger of fire.
DO’S & DON'T’S
No flame based cooking should be done below the chimney.
While frying do not leave the cooking oil unattended as it may flare up and cause fire.
Clean all the oily residues on surface frequently to avoid fire.
The minimum distance between the cooktop and the bottom of the chimney must be 750 mm.
Make sure that the supply voltage ratings correspond with the specifications provided in the User’s
Guide.
Before using the chimney for the first time please ensure that all plastic films on baffle filter and stainless
body are removed.
Wash the filters as often as possible at least once in 10-15 days in normal operating conditions.
When performing maintenance operations, disconnect the plug from the socket.
No repair work should be carried out by any unauthorised person.
Chimney should be used as per the directions given in the User’s Guide.
Do not allow children to operate the chimney.
In case the chimney is installed in the under construction Kitchens, it is advisable to install the
Chimney, test it and then again remove the same and pack in the box. As if the Chimney is left
unattended the paints, chemicals, dust & moisture etc if not cleaned timely may result in rust formation
which will not be covered in the warranty.
Exhaust mode
Re-circulation mode
(Available in select model)
This mode is used when no exhaust duct to the outdoors is available. The air is purified by an active carbon
filter and recycled into the room.
The carbon filter is an optional attachment and must be procured in this case.
Remove the metal filters. Insert the carbon filters and rotate it to lock at the side of the hood. For effective
functioning the carbon filters need to be replaced after 3-4 months.
Electric connection
Make sure that the supply voltage rating correspond with the specifications provided In the User’s Guide.
The chimney must be connected by the spigot (supplied as part of the hood) to a duct to vent all the
exhausted air outside the kitchen. Over horizontal areas, if any, the duct must be slanted about 10%
downwards.
The maximum recommended length of ducting is 10 feet with a maximum of two bends. The suction power
of the chimney considerably decreases in case the length of the duct and number of bends increases
further.
USAGE