background image

LIFETIME WARRANTY 

(On select models only)

To avail the lifetime warranty you need to register online within 90 days of your purchase.

To register online you need to do the following:
Log on to glen website 

www.capellaindia.com

Click on lifetime warranty, it will open a window there you need to feed the Lifetime Warranty unique ID, 
model number and serial number of the chimney hood. 
For LTW unique ID and serial number you need to open the chimney hood. You will find two labels one for 
LTW unique ID and other for serial number. 

(Never ever remove the labels otherwise the warranty becomes void)

.

If all your information is correct and matches with our record another window will open wherein you will 
need to fill the personal details like name & address etc.

Once  you  complete  the  information  and  press  submit  a  confirmation  number  will  be  given  for  future 
reference. Also one confirmation mail with all the details will be sent to your email id. You are requested to 
take a printout of the same and keep it safe. In case of any repair in future you will need to show this mail to 
the service engineer to avail the lifetime warranty.

Note 

: The offer lapses if not registered with in 90 days of date of purchase. 

The chimney should be used as per the directions given in the user's guide. Defects caused by improper 
or reckless use are not covered. 
Any  damages  due  to  the  use  of  abrasive  chemicals,  or  usage  in  extremely  adverse  atmosphere,  i.e. 
abnormally corrosive / alkaline / acidic is not covered under warranty. 
The warranty will not cover Chimneys used for commercial purposes. 
The chimney should have been serviced and cleaned at regular intervals at-least once in two months by 
a Glen Authorised Service Centre failure to comply with this will render this warranty void. The cost of 
any such service will be borne by the customer. 
No installation / modification / alteration / service of any nature is made in the chimney by unauthorised 
persons. The Installation Charges are to be borne by the customer. 
Only the parts covered under LTW will be replaced free. The labour charges for the replacement of under 
warranty parts will be borne by the customer. The visit charges (within municipal area only) of Rs. 250/- 
(subject to change from time to time) will be charged extra.
This chimney has been designed to last a long time and depending on the up-keep & maintenance by the 
customer the Chimney may last a long time but for the purpose of Life Time Warranty the Life of the 
Chimney will be taken as 7 years from the date of Purchase of the Chimney.
The warranty is not valid for any damages arising due to erratic power supply. 
The warranty is not valid in case chimney is used on Inverter or Generator. 

The Life Time Warranty is offered on the following conditions:

Switch  on  the  chimney  5  minutes  before  you  start  cooking.  Before 
using the chimney please ensure that all plastic films on the filter and 
stainless steel body are removed.
The  push  button/slider  control  have  three  speed  settings.  Kindly 
choose the speed as per your requirement.

Two lamps are provided in the chimney to enable proper lighting up of the cooking area. The light works 
independently of whether the fan is switched on or off, as it is provided with separate on/off switch.

Light

INSTALLATION

The chimney must be mounted over the center of the cooking area. The minimum 
distance between the cooktop and the bottom of the chimney must be 750 mm. 

If there is no outer waste-pipe for the exhaust, an air outlet with a diameter of 
130 mm must be made through the wall. The exhaust pipe from the top of the 
chimney, should be connected to the exhaust.

Fastening the chimney to the wall

Mark  the  position  of  the  holes  on  the  wall.  Before  drilling  make  sure  that  no 
wiring and tube will be damaged. Drill two fastening holes, drive in the wall 
plugs and screw in the screw until their heads are about 6 mm from wall.

Place the chimney to the wall in order to check that it seats properly. Then mark the position of the two 
holes. Take it off from the wall now, drill the holes and fit the plugs.
Place the hood once again to the wall, and introduce the screws from the inside of the appliance. 

The product can be used in re-circulation or the exhaust mode. It is however 
recommended that wherever possible it should be used in exhaust mode for 
best results.

Your chimney is provided with option of ducting from back or top depending on 
the site. Before installation in case of air exhaust from back remove the cover 
from back and fix it to top air outlet. now take the spigot and fit in the back air 
outlet.

750 mm

750 mm

MAINTENANCE

When  performing  maintenance  operations,  disconnect  the  plug  from  the 
socket. 
The efficiency of the chimney depends on the condition of the filters. 
The filters should be washed as often as possible but at least once in10 to 15 
days in normal operating conditions. 
The baffle & aluminium filters can be removed easily by unlocking. 
Dip the filter for 10-15 minutes into a boiling hot soap solution and then wash in 
running water. Dry and reinstall the filter.  

The chimney surface should be cleaned with a damp cloth. No abrasive chemicals should be used.

Frequent cleaning of filter is very important to avoid danger of fire.

DO’S & DON'T’S

No flame based cooking should be done below the chimney.
While frying do not leave the cooking oil unattended as it may flare up and cause fire.
Clean all the oily residues on surface frequently to avoid fire.
The minimum distance between the cooktop and the bottom of the chimney must be 750 mm.
Make sure that the supply voltage ratings correspond with the specifications provided in the User’s     
Guide.
Before using the chimney for the first time please ensure that all plastic films on baffle filter and stainless 
body are removed.
Wash the filters as often as possible at least once in 10-15 days in normal operating conditions.
When performing maintenance operations, disconnect the plug from the socket.
No repair work should be carried out by any unauthorised person.
Chimney should be used as per the directions given in the User’s Guide. 
Do not allow children to operate the chimney.

In  case  the  chimney  is  installed  in  the  under  construction  Kitchens,  it  is  advisable  to  install  the 
Chimney,  test  it  and  then  again  remove  the  same  and  pack  in  the  box.  As  if  the  Chimney  is  left 
unattended the paints, chemicals, dust & moisture etc if not cleaned timely may result in rust formation 
which will not be covered in the warranty.

Exhaust mode

Re-circulation mode 

(Available in select model)

This mode is used when no exhaust duct to the outdoors is available. The air is purified by an active carbon 
filter and recycled into the room.
The carbon filter is an optional attachment and must be procured in this case.
Remove the metal filters. Insert the carbon filters and rotate it to lock at the side of the hood. For effective 
functioning the carbon filters need to be replaced after 3-4 months.

Electric connection

Make sure that the supply voltage rating correspond with the specifications provided In the User’s Guide.

The  chimney  must  be  connected  by  the  spigot  (supplied  as  part  of  the  hood)  to  a  duct  to  vent  all  the 
exhausted  air  outside  the  kitchen.  Over  horizontal  areas,  if  any,  the  duct  must  be  slanted  about  10% 
downwards.

The maximum recommended length of ducting is 10 feet with a maximum of two bends. The suction power 
of  the  chimney  considerably  decreases  in  case  the  length  of  the  duct  and  number  of  bends  increases 
further. 

USAGE

Отзывы: