29
TROUBLESHOOTING
TROUBLESHOOTING
Burner will not light using igniter
LP gas tank valve is closed
LP gas tank is low or empty
LP gas leak
Battery needs to be changed
Electrode and burners are wet
Electrode cracked or broken — sparks at crack
Wire loose or disconnected
Wire is shorting (sparking) between
igniter and electrode
Bad igniter
Make sure regulator is securely attached to the LP gas tank per
“Installing LP Gas Tank,” then turn LP gas tank valve to “OPEN”
([FKDQJHUH´OORUUHSODFH/3JDVWDQN
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Replace the “A$A” battery (follow assembly step for inserting battery)
Wipe dry with cloth
Replacement part(s) may be needed — contact Customer Care at
1-888-670-6684
Replacement part(s) may be needed — contact Customer Care at
1-888-670-6684
Replacement part(s) may be needed — contact Customer Care at
1-888-670-6684
Replacement part(s) may be needed — contact Customer Care at
1-888-670-6684
1RJDVµRZ
Check if LP gas tank is empty
D ,IHPSW\H[FKDQJHUH´OORUUHSODFH/3JDVWDQN
E ,I/3JDVWDQNLVQRWHPSW\UHIHUWRª6XGGHQGURSLQJDVµRw or
UHGXFHGµDPHKHLJKW«VHHEHORZ
LP gas leak
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Coupling nut and regulator not fully connected
Turn the coupling nut about one-half to three-quarters additional
turn until solid stop. Tighten by hand only — do NOT use tools
2EVWUXFWLRQRIJDVµRZ
1. Clear burner/venturi tube
2. Check for bent or kinked hose
Disengagement of burner to valve
Re-engage burner and valve
Spider webs or insect nest in burner/venturi tube
Clean burner/venturi tube
Burner ports clogged or blocked
Clean burner ports
LP gas tank is low or empty
([FKDQJHUH´OORUUHSODFH/3JDVWDQN
Burner will not light with match