Product name

Model No.

Rated Heat Output

Fuel

Gas Supply

Manifold Pressure

Orifice Size (diameter)

Gas Supply Pressure

York Outdoor Fire Table

4

SPECIFICATION

IMPORTANT SAFETY INFORMATION AND PRECAUTIONS

085-1558-6

30,000 BTU/HR

Propane-LP

20 lb (9 kg) LP-Gas cylinder

11" W.C.

1.74 mm   

Max 250 PSI

   When the appliance is for connection to a fixed piping system, the installation must conform 
with local codes, or in the absence of local codes with the National Fuel Gas Code, ANSI 
Z223.1/NFPA54; International Fuel Gas Code, Natural Gas and Propane Installation Code, CSA 
B149.1; or Propane Storage and Handling Code, B149.2, as applicable. 
   The LP gas supply cylinder to be used must be:
   1-Constructed and marked in accordance with the U.S. Department of Transportation (D.O.T.)  
Specifications for LP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for Trans-
portation of Dangerous Goods and Commission, CAN/CSA-B339 as applicable;
   2-Provided with a listed overfilling prevention device;
   3-Provided with a cylinder connection device compatible with the connection for the appliance.

    

Always place the appliance on a firm and level surface. 

    

Solid fuels may not be burned in this gas appliance. When using decorative lava rocks, use only 

provided lava rocks (INCLUDED).

    

The appliance must be used only outdoors in a well-ventilated space and must not be used in 

a building, garage or any other enclosed area.

    

When in use, keep the appliance area clear and at least 40" / 101.6 cm side clearance from com-

bustible materials, gasoline and other flammable liquids and vapours. Do not use the appliance 
under overhead combustible surfaces. Certain items or materials, when stored under the appli-
ance or nearby, will be subjected to radiant heat and could be damaged. 

    

When in use, keep cylinder at least 30" / 76.2 cm side clearance from fire table. DO NOT trip 

over the gas pipe between fire table and cylinder when passing through, to prevent cylinder 
from tipping over.

Содержание 085-1558-6

Страница 1: ...Fire Table MODEL N0 085 1558 6 L FT1109PST B ASSEMBLY INSTRUCTIONS Toll free 1 844 786 5691 IMPORTANT Please read this manual carefully before beginning assembly of this product Keep this manual for future reference ...

Страница 2: ...nstructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable odour and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use should not be stored in the vicinity of this or any other appliance DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odour Using it in a...

Страница 3: ...view Parts list Assembly Location Setup Gas connection Operation Leak test Lighting Storage and maintenance Troubleshooting Limited warranty IMPORTANT 3 4 4 5 6 7 9 9 10 9 10 11 8 7 8 8 Please take time to read these instructions thoroughly and follow each step carefully for safe and easy operation Keep this manual for installer and consumer future reference use ...

Страница 4: ...Dangerous Goods and Commission CAN CSA B339 as applicable 2 Provided with a listed overfilling prevention device 3 Provided with a cylinder connection device compatible with the connection for the appliance Always place the appliance on a firm and level surface Solid fuels may not be burned in this gas appliance When using decorative lava rocks use only provided lava rocks INCLUDED The appliance m...

Страница 5: ...been under water LP gas supply cylinder to be used must be constructed and marked in accordance with the specifi cations for LP gas cylinders of the Canadian Department of Transportation DOT The cylinders supply system must be arranged for vapour withdrawal and the cylinder must include a collar to protect the cylinder valve Use only 20 lb 9 kg LP Gas cylinders Do not burn wood or any other materi...

Страница 6: ...6 EXPANDED VIEW H1 H2 ...

Страница 7: ...t the lid A onto the table top B No Description Qty A 1 1 1 1 0 6KG 9 lb 4 kg Lid FT1109XXB01 Main body FT1109XXB02 Tank rack FT1109XXB03 Lava rock LPHSS23X1H Fibre rock LPXWQ06SHX B C H1 H2 Step 1 Place the tank rack C next to the fire table at least a distance of 30 76 cm as above shown above Step 2 30 76 2 cm ...

Страница 8: ...ery into the bottom of battery box as shown in Fig 2 Then screw the battery box as shown in Fig 3 Note If the battery of the pulse electronic igniter runs out of power please replace with new battery 1 Check the pressure regulator and place the tank rack next to the fire table as shown in Fig 4 2 Unscrew the locking device on tank rack per Fig 5 1 place cylinder on the rack and then tighten lockin...

Страница 9: ...re for assistance 1 844 786 5691 5 If the connection does not leak continue to the next step 1 Make sure control valve is OFF 2 Turn on gas tank valve 3 Press in and turn control valve knob counter clockwise to LOW to light See the figure to the right 4 If burner is lit continue pressing in the control valve knob for a minute to heat the thermocouple 5 When control valve knob is released the burne...

Страница 10: ...air passageways of the fire table be kept clean If you disassemble the burner when cleaning the fire table please reassemble it according to the picture on the right to make sure the burner induction tunnel is on and exactly covers the orifice base It is imperative that the control compartment burner and circulating air passageways of the fire table be kept clean It is recommended not to disassemb...

Страница 11: ... not been assembled installed or operated according to the instructions or subjected to abuse improperly treated neglected rusted by exposure to the elements misused and or if any repairs maintenance or service has been done by an unauthorized person Returns must be properly packaged and returned to the dealer from whom the product was acquired The manufacturer distributor and retailer will not be...

Отзывы: