background image

Innovative Lighting Products

Followspot Operating Instructions

V 1.1   2/25/21

8

1092 West Atlanta Street, SE • Suite 600 • Marietta, GA 30060 • 888-252-5912 • 

[email protected]

 • cantousa.com

OPERATION OF THE FOLLOWSPOT:

 

1.  Plug the followspot to the electronic PSU. Please note that each followspot has been factory tested with relevant  

 

 

PSU. Both units are recognized by a serial number (on the outer box, on the units and on the front cover of the  

 

 

instruction manual). Make sure you match each followspot to the relevant PSU.

 

2.  Connect the PSU to your 120 volt power supply.

 

3.  Turn to the right (1/4 turn) the on/off selector on the PSU (fans will start working).

 

4.  A RED LIGHT comes up from inside the ballast (visible from the ventilation slots beside the on/off selector

 

5.  WAIT UNTIL THE RED LIGHT TURNS GREEN AND FINALLY CYAN (GREEN+BLUE) (3/5 seconds)

 

6.  Turn to the right (1/4 turn) the on/off selector positioned at the back of the luminaire (lamp is on).

The lamp will only switch on once the green light in the ballast is on. Should you have waited too long the PSU will not have 

found the lamp when trying to strike it. The ballast will try for 10 times and then stop, assuming no lamp is inserted after 

which the lamp will not go on. In this case please switch the PSU off and start again

CAUTION: ONLY PERFORM SERVICING AFTER THE UNIT HAS BEEN COOLED DOWN, UNPLUGGED 

FROM POWER SOUCRCE, AND OFF FOR 30 MINUTES.

LAMP SETTINGS AND ALIGNMENT:

For an optimum performance of the followspot, lamp alignment must be checked and performed each time a new lamp is 

fitted or an old lamp is replaced. Please proceed as follows:

 

1.  Turn the followspot on and project the light on a flat surface about 3-6 feet away.

 

2.  Completely de-focus the zoom so that you can see the lamp projected on the surface.

 

3.  Close the douser to a slightly bigger size than the height of the lamp. You should see a circle of light and the 

 

 

image of the lamp on the surface.

 

4.  If the lamp is not exactly centered in the circle of the light, set the alignment by loosening/tightening one of the 

 

 

three adjustment screws positioned at the bottom of the lamp holder block until the lamp is aligned.

CAUTION: ADJUST EACH SCREW VERY SLOWLY IN ORDER NOT TO CAUSE THE LAMP TO TOUCH THE 

OPTICAL SYSTEM. THIS WILL CAUSE BOTH THE LAMP AND THE FRONT LENS TO EXPLODE.

Once the alignment is correct, you can begin using the followspot.

Содержание A10857190

Страница 1: ...et your requirements but if for any reason this should not be the case we ask that you contact us directly at 888 252 5912 to help address your needs We wish to provide all of our customers with the b...

Страница 2: ...g content page 4 Mounting the spigot page 4 Mounting the color changer page 5 Mounting the iris diaphragm page 5 Shutter blades page 6 Adjusting the yoke page 6 Wiring page 6 Voltage page 6 Frequency...

Страница 3: ...D ON WARNING HIGH VOLTAGE IGNITION MSR MSD ONLY U V RAYS The lamps used on the discharge models Canto 575 700 1200 1500 and 2000 MSR MSD emit UV rays Protect your eyes and never look directly at the s...

Страница 4: ...light case a Followspot b Electronic ballast unit c Iris diaphragm d 7 color magazine e Heavy duty followspot tripod f Philips MSR Gold 1500 2 FastFit lam PGJX50 7500K 750 hours TRIPOD STAND Tripod Ma...

Страница 5: ...owspot when viewed from behind and hang it to the previously positioned screws 4 Release the color filters of the color changer in order to have access to the screws and tighten them 5 Ensure the colo...

Страница 6: ...e the plug conforms to the relevant local safety requirement and UL electrical standards Make sure the plug you are fitting withstands the lamp power load This fixture must be grounded To perform a co...

Страница 7: ...eplacing a lamp use a proper thermal protection for your hands ex gloves in case the lamp is still hot b Protect the lamp from abrasion and scratches Do not install or use a cracked or broken lamp In...

Страница 8: ...when trying to strike it The ballast will try for 10 times and then stop assuming no lamp is inserted after which the lamp will not go on In this case please switch the PSU off and start again CAUTIO...

Страница 9: ...m performance of the product a regular maintenance service should be carried out Please make sure the product is cold and disconnected from power supply when doing this Use a clean cloth and non abras...

Страница 10: ...hased this product and 10 years on any LED array In case of any issues we strongly recommend you call us at 888 252 5912 or contact the local dealer who supplied the product to you In any case please...

Отзывы: