background image

Section figure

Figure A: temporary fixing

3

Attach the front frame connecting parts

Attach the front frame connecting parts

In case of in-line connection of M-connecting type

Insert the back plate into the connecting material

Hold the connecting material from upside and set in the front frame connecting parts to the connecting material.

The front frame connecting parts can be hooked to the connecting material temporarily by pushing up (see figure A).

Position the back plate at equal interval and set in the front frame connecting parts.

Fix the front frame connecting parts to the back plate inserted into

the connecting material with small truss screw 

5×15×10

.

Set in

Insert

Front frame

connecting part

Back plate

Connecting material

Front frame

connecting part

Small truss screw

5×15×10

Back plate

Connecting material

Front frame

connecting part

Temporary fixing

Back plate

Small truss screw

5×15×10

Equal interval

Equal interval

Equal interval

Equal interval

Front frame

Connecting material

Front frame

connecting part

Back plate

Small truss screw

5×15×10

70

210(W22)

70

210(W22)

4.5

4.5

70

210(W22)

70

210(W22)

Connecting material

(Strike)

Front frame

Equal interval

Equal interval

10

6

Содержание PJR Series

Страница 1: ...lides down from the building roof directly There is a possibility that products are damaged by snow falling When installing it besides wall etc keep enough clearance between the product and the wall d...

Страница 2: ...st type adjusting to post position of 3 post type Strike the front frames and do sealing work below figure A part Peel the back sheet of water proof cover and attach the water proof cover on the joint...

Страница 3: ...JRG B 1 2 PJRG B PJRG B 1 3 2 PJRG B PJRG B 1 9 8 5 4 PJRG B PJRG B 1 Washer 8 8 4 PJRG B PJRG B 1 16 8 PJRG B PJRG B 1 Hexagon bolt M8 85 8 4 PJRG B PJRG B 1 Nut M8 8 4 PJRG B PJRG B 1 1 PJRG B PJRG...

Страница 4: ...the post for D18 In case of f implant the post for D33 175 1mm deeper than the post for D18 In case of g implant the post for D24 36 5mm deeper than the post for D21 In case of h implant the post for...

Страница 5: ...5 55 5 56 55 5 56 56 55 5 56 55 54 5 D1 D2 18type 18type 21type 21type 24type 24type 25type 25type 27type 27type 30type 30type 33type 33type 18type 21type 18type 24type 18type 25type 18type 27type 18...

Страница 6: ...rval and set in the front frame connecting parts Fix the front frame connecting parts to the back plate inserted into the connecting material with small truss screw 5 15 10 Set in Insert Front frame c...

Страница 7: ...connecting cap Insert the connecting cap to connecting material and fix with drilling screw 4 10 8 Do sealing work to the touching part Drilling screw 4 10 8 Front frame Connecting cap Connecting mat...

Страница 8: ...WB 48 70 4675 4 WB 48 70 D 4223 2 WB 42 70 4083 2 WB 42 70 Post Internal WB 51 4811 2 Post Internal WB 54 5126 Post Internal WB 60 5715 4 Post Internal WB 42 3943 2 Post Internal WB 48 4535 4 Post Cen...

Страница 9: ...OM ENDS FOOTING DETAILS PIT FOOTING 900 x 900 x 900 PILE FOOTING 450 x 1500 BMS450 SMS65 METAL SLEEVE ADVANTAGE 1 Eliminates error in height The metal sleeves are inserted into the concrete footing an...

Страница 10: ...of edge of SHS 130 Keep brace rod clear of edge of SHS Footing 900x900x900 Footing 450 dia x 1500 65 x 65 x 3 SHS Existing Ground level FRONT ELEVATION FRONT ELEVATION Footing 450 dia x 1500 65 x 65 x...

Страница 11: ...Existing concrete driveway Baseplate to cover concrete access hole Ramset Chemset 101 Plus with N16 Grade 500 Threaded Rod Hole depth Min 200mm Footing 900x900x900 Footing 450 dia x 1500 Existing conc...

Отзывы: