① :
In case of
D18 + D18 D=3712mm
② :
In case of
D21 + D21 D=4318mm
③ :
In case of
D24 + D24 D=4922mm
④ :
In case of
D27 + D27 D=5524mm
⑤ :
In case of
D30 + D30 D=6126mm
⑥ :
In case of
D33 + D33 D=6728mm
a :
In case of
D18 + D21 D=4014mm
b :
In case of
D18 + D24 D=4317mm
c :
In case of
D18 + D27 D=4618mm
d :
In case of
D18 + D30 D=4919mm
e :
In case of
D18 + D33 D=5220mm
f :
In case of
D21 + D24 D=4620mm
g :
In case of
D21 + D27 D=4921mm
h :
In case of
D21 + D30 D=5222mm
i :
In case of
D21 + D33 D=5523mm
j :
In case of
D24 + D27 D=5223mm
k :
In case of
D24 + D30 D=5524mm
l :
In case of
D24 + D33 D=5825mm
m :
In case of
D27 + D30 D=5825mm
n :
In case of
D27 + D33 D=6126mm
o :
In case of
D30 + D33 D=6427mm
In case of a, implant the post for D21 21.1mm deeper than the post for D18.
In case of b, implant the post for D24 41.6mm deeper than the post for D18.
In case of c, implant the post for D27 62.6mm deeper than the post for D18.
In case of d, implant the post for D30 83.6mm deeper than the post for D18.
In case of e, implant the post for D33 104.7mm deeper than the post for D18.
In case of f, implant the post for D24 20.4mm deeper than the post for D21.
In case of g, implant the post for D27 41.5mm deeper than the post for D21.
In case of h, implant the post for D30 62.5mm deeper than the post for D21.
In case of i, implant the post for D33 83.6mm deeper than the post for D21.
In case of j, implant the post for D27 21.1mm deeper than the post for D24.
In case of k, implant the post for D30 42.1mm deeper than the post for D24.
In case of l, implant the post for D33 63.1mm deeper than the post for D24.
In case of m, implant the post for D30 21.0mm deeper than the post for D27.
In case of n, implant the post for D33 42.1mm deeper than the post for D27.
In case of o, implant the post for D33 21.1mm deeper than the post for D30.
1
Installation of connecting material
Installation procedure
After installing the roof as below figure, install the connecting material on the front frame.
※
Before installing the roof panels, install the connecting material.
■
Post out/out dimension
Please implant the post as below in order to
adjust the top end of the roof.
D=D1+D2+20
D1
20
D2
4