44
Procedure
“Starting protocol” Setting
Select “Setup Properties” from the “View” menu.
Viewer for PC Settings
From the “Setup Properties” window, you can specify a range of settings governing the operation of
the Viewer for PC.
Normally, there is no need to alter these settings.
1
2
Specify whether connection to the camera server is to be made using the WebView-TCP
protocol or the WebView-HTTP protocol.
●
“Auto select connection”
Use this setting when you do not know
the details of the connection
environment. When this option is
selected, the viewer first tries to connect
using WebView-TCP and then tries
WebView-HTTP.
●
“WV-TCP protocol connection”
This setting uses the WebView-TCP
protocol used specifically by WebView
for TCP connections. To penetrate
firewalls with this protocol, a dedicated
application gateway is required.
Viewing video from behind a firewall
To view video from behind a firewall using the WebView-HTTP protocol, you
must specify the HTTP proxy settings. You can set the same settings as the
HTTP proxy specified in your Web browser. If you want to access video from
behind a firewall, select WV-HTTP protocol. (See P.45 for details.)
●
“WV-HTTP protocol connection”
This setting uses the WebView-HTTP protocol, which is the WebView protocol that conforms
to the ordinary HTTP standard. The HTTP proxy can be used as is and the firewall can be
passed.
●
“Receive audio data”
Remove the tick if you do not want to receive audio data.
c
Note
Select protocols from the “Options at starting with WVH file” in the “Starting protocol” tab.