127
By linking two types of events, a single event is triggered. Select AND/OR for the event linking method.
Able to set the operations to perform, such as recording video or sending e-mail notifications, when a linked event is
triggered.
Note
• Able to check the linked event status on the [Event and Input/Output Menu] of the Camera Viewer (P. 51).
Linked Event 1 to 4
Able to register up to four linked events.
It is possible to link the following events: [Volume Detection], [External Device Input], [Timer] and [Intelligent Function].
[Linked Event]
Select whether to use a linked event.
[Event Linking Method]
Select the event linking conditions.
When [AND] is set, a new linked event is triggered if both event types selected with [Event 1] and [Event 2] are triggered. In
this case, set [Event Order] and [Event Gap].
When [OR] is set, a new linked event is triggered if either event type selected with [Event 1] or [Event 2] is triggered.
[Event Order]
Able to select the trigger order of two events when [Event Linking Method] is set to [AND].
If set to [None], the order will not be considered.
[Event Gap (seconds)]
Enter the trigger interval between two events when [Event Linking Method] is set to [AND].
A new linked event is triggered if the second event triggers within the specified interval after the first event was triggered.
Event 1, 2
Specify the two events to be linked. The settings are the same for both.
[Event Type]
Select the event type for linking.
[Volume Detection]
Select an ON event or an OFF event in [Volume Detection Status] to trigger a linked event .
[External Device Input]
For [External Device Input], select the external device input to use.
Select an active event or inactive event to trigger a linked event in [External Device Input Status].
[Event] > [Linked Event]