background image

4/4 

References 

■ User’s manual 

Installation CD¥Document¥English¥Manual 
UsersManual_EN.pdf 

■ Application software user’s manual 

Installation CD¥Document¥English¥Manual 
Application_UsersManual_EN.pdf 

CANON USA, INC. 

 

3300 North First Street San Jose, CA 95134 

Phone : +1-408-468-2000, Fax : +1-408-468-2219 

CANON Europa N.V. 

Bovenkerkerweg 59-61, 1185 XB AmstelveenThe 

Netherlands 

Phone : +31-20-545-5229  

CANON MARKETING JAPAN INC. 

 

2-16-6, Kounan, Minato-ku, Tokyo, 108-8011, Japan  

Phone : +81-3-3740-3336 Fax :+81-3-3740-3356  

CANON INC. 

 

30-2, Shimomaruko 3-chome, Ohta-ku, TOKYO, 146-

8501, Japan 

 

• The contents of this document may change without 

prior notice. 

• If you have any questions or find any errors or 

omissions, please contact us. 

CUD-K003-E01 

Apr. 2017 

Quick Manual 

5) Click Connect to Device on the menu bar to search for 

connectable measuring devices. 

Menu bar 

6) If there is no connectable measuring device, a message 

appears on the menu bar, and the background color 

changes to gradual dark pink. 

  Check the connection condition, and press Connect to 

Device again. 

7) If the connection is successful, a message appears on the 

menu bar, and the background color changes to gradual 

green. 

 

 The battery level of the measuring device is displayed as 

well. 

8) When the connection is complete, click Measure on the 

main window to start a measurement. 

This completes the setup procedure. 

Содержание RA-532H

Страница 1: ... first time For further details see the user s manual in the CD ROM included with the product Introduction 1 4 Product configuration RA 532H Surface Reflectance Analyzer Calibration unit Case and CD ROM User s manual Application software Installer Surface Reflectance Analyzer configuration Surface Reflectance Analyzer Software This software measures gloss haze and image clarity and draws graphs of...

Страница 2: ...rtup screen 3 To calibrate the measuring device you use the accompanying calibration unit Check that no dust or stains are on the standard plate and set the measuring device in the calibration unit 4 Press on the measuring device to execute calibration When the message Calibrating disappears and the main screen appears calibration is complete SCAN Measuring screen Main screen One dimensional BRDF ...

Страница 3: ...nt and click Next Step 4 Starting and ending the application software This section explains the procedure from starting the app to connecting the measuring device 2 There are two available types of connections to the PC and you set this on the measuring device The default is USB connection 1 If you set the connection type on the measuring device to USB connect the PC and measuring device through U...

Страница 4: ...ntents of this document may change without prior notice If you have any questions or find any errors or omissions please contact us CUD K003 E01 Apr 2017 Quick Manual 5 Click Connect to Device on the menu bar to search for connectable measuring devices Menu bar 6 If there is no connectable measuring device a message appears on the menu bar and the background color changes to gradual dark pink Chec...

Отзывы: