3-15
CHAPTER 3. REPAIR INSTRUCTION
Fig. 3-15 LITHIUM (+) CONTACT, LITHIUM (-) CONTACT
c
MAIN FRAME
XA4-9170-407
METAL
M1.7
(SELF TAP)
4.0mm
LITHIUM (-) CONTACT
LITHIUM (+) CONTACT
LITHIUM (-) LEAD
LITHIUM (+) LEAD
(1)-2
(2)-1
(1)-1
(2)-2
Soldering
Soldering
NOTE (Assembling)
NOTE (Assembling)
c
c
2.13 LITHIUM (+) CONTACT, LITHIUM (-) CONTACT
(1) LITHIUM (+) CONTACT, LITHIUM (+) LEAD
1. Remove the screw
c
and remove the LITHIUM (+) CONTACT.
2. Remove soldering and remove the LITHIUM (+) LEAD.
NOTE (Assembling)
After soldering, apply the DIA BOND1663G.
(2) LITHIUM (-) CONTACT, LITHIUM (-) LEAD
1. Remove the screw
c
and remove the LITHIUM (-) CONTACT.
2. Remove soldering and remove the LITHIUM (-) LEAD.
NOTE (Assembling)
After soldering, apply the DIA BOND1663G.
Содержание PowerShot A100
Страница 1: ......
Страница 4: ......
Страница 6: ......
Страница 40: ......
Страница 42: ......
Страница 50: ......
Страница 52: ......
Страница 94: ...3 42 CHAPTER 3 REPAIR INSTRUCTION 4 Make sure to appear err 0 on the bottom line ...
Страница 96: ......
Страница 105: ...PowerShot A200 PowerShot A100 Pg5 Accessories 3 Camera User Guide Software Starter Guide System Map 1 2 3 ...
Страница 109: ......
Страница 111: ......
Страница 121: ...C CANON INC 2002 01 June 2002 3 2 FLASH UNIT FLASH PCB ASS Y SOLDERING SIDE FLASH PCB ASS Y COMPONENT SIDE ...
Страница 122: ...C CANON INC 2002 01 June 2002 3 3 OPR PCB ASS Y ...
Страница 123: ...C CANON INC 2002 01 June 2002 3 4 RLS PCB ASS Y ...
Страница 124: ...C CANON INC 2002 01 June 2002 3 5 BL FPC ASS Y ...
Страница 126: ...PowerShot A100 A200 AF Chart ...
Страница 127: ......
Страница 128: ...PowerShot A100 A200 AF Chart ...
Страница 129: ...Dimensions 467 83mm 370 89mm 96 94mm 346 98mm 260 0mm 93 00mm ...