CHAPTER 11 TROUBLESHOOTING
COPYRIGHT © 1999 CANON INC. CANON PC800s/900s REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
11-87
Code
Cause
Description
• The main motor (M1) is fault.
• The DC controller PCB is faulty.
• The composite power supply PCB is
faulty.
• The DC controller PCB is faulty.
• The scanner home position sensor
(PS1) is faulty.
• The scanner/lens drive motor (M2)
is faulty.
• The DC controller PCB is faulty.
• The lens home position sensor
(PS2) is faulty.
• The scanner/lens drive motor (M2)
is faulty.
• The lens cable is faulty.
• The DC controller PCB is faulty.
• The scanning lamp (LA1) is faulty.
• The DC controller PCB is faulty.
• The composite power supply PCB is
faulty.
• The DC controller PCB is faulty.
• The composite power supply PCB is
faulty.
• The frequency of the power supply
is faulty.
• The composite power supply PCB is
faulty.
• Data communication between the
copier and the ADF (faulty).
• The DC controller PCB is faulty.
• The composite power supply PCB is
faulty.
• The rotation of the main motor deviates
(indicated by MLOCK=0) for 1 sec or
more while the main motor drive signal
(MMD=1) is being generated.
• The actual output value of the compos-
ite power supply high voltage is differ-
ent from the setting value twice in
succession.
• The scanner home position is not
detected within 10 sec after the scanner
has turned on.
• The scanner does not leave the home
position after it has turned on.
• The lens hoe position is not detected
after the lens has moved the maximum
travel distance.
• The lens does not leave the home
position after it has turned on.
• The lamp ON detection signal is not
detected for 1 sec or more in the
presence of the scanning lamp On
signal.
• The lamp ON detection signal is
detected for 1 sec or more in the
absence of the scanning lamp ON
signal.
• A fault in the communication between
DC controller PCB and composite
power supply PCB is detected.
• The interval between zero-cross signals
is in excess of the allowed interval.
• The communication with the copier is
interrupted for 5 sec or more; the
communication is monitored at all
times.
• During a copying run, the +24 V power
deviates from the control value by
±20%.
The keys on the
control panel
are locked
without error
code indication.
( )
Содержание PC800 Series
Страница 6: ...COPYRIGHT 1999 CANON INC CANON PC800s 900s REV 0 AUG 1999 PRINTED IN JAPAN IMPRIME AU JAPON i v ...
Страница 12: ......
Страница 34: ......
Страница 36: ......
Страница 48: ......
Страница 50: ......
Страница 92: ......
Страница 94: ......
Страница 122: ......
Страница 124: ......
Страница 162: ......
Страница 164: ......
Страница 180: ......
Страница 206: ......
Страница 240: ......
Страница 242: ......
Страница 256: ......
Страница 263: ......
Страница 265: ......
Страница 355: ......
Страница 359: ...A 4 COPYRIGHT 1999 CANON INC CANON PC800s 900s REV 0 AUG 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 373: ...A 18 COPYRIGHT 1999 CANON INC CANON PC800s 900s REV 0 AUG 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 383: ......
Страница 393: ...0899AB2 135 1 PRINTED IN JAPAN IMPRIME AU JAPON This pubication is printed on 70 reprocessed paper ...