5.2
Check the air system
5.2.1
Check the waste reservoirs of the air system
Rev 1,2,3,4
–
Check if the waste reservoirs from the air inlet unit, contains fluid.
In case there is waste in the reservoirs, put a cup
below the nozzles and open them to collect any
waste. Close the nozzles when the reservoir is
empty.
In case there is often waste in the reservoirs,
initiate an check on the quality of the pressured air.
Apparently there is too much oil/water in the air.
5.2.2
Check the air pressure
Rev 1,2,3,4
–
The air pressure depends on the hardware level of this system.
The pressure in this system must be: . . . . . . Bar.
(To be completed by local service)
In case the pressure is too low, inform the local service organization.