Océ VarioPrint 6000+ Customer Expectations Document
Version 1
Océ VarioPrint 6000+ Series Customer Expectations Document
Page 17
4.2 Power Requirements for the Main Unit and Optional Accessories
Part or Accessory
Power Supply
Power Receptacle
Length of Power
Cord
Main Unit (Print Engine Module)
3 Phase
208-240 V/30 A outlet
NEMA L15-30R
15’ (4.6 m)
Single Phase
208-240 V/50 A outlet
NEMA 14-50R
15’ (4.6 m)
PIM 1
115 V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
PIM 2
115 V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
PIM 3
115 V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
High Capacity Stacker Only
115 V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
High Capacity Stacker with Set
Finisher
115 V/15 A outlet
NEMA 5-15R
15’ (4.6 m)
Media Enhancement Module
100-240 V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
PRISMAsync Controller
Powered by the Main Unit
—
—
Print Guard Unit
115 V/20 A outlet x 2
NEMA 5-20R x 2
12’ (3.6 m) x 2
GBC PowerPunch
110 V/20 A outlet
NEMA 5-20R
12’ (3.6 m) x 2
iXDP
Single Phase
115 V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
DFS30 Tape Binder
110 V/20 A outlet
NEMA 5-20R
12’ (3.6 m)
BLM200
Single Phase
120 V/15 A outlet
NEMA 5-20R
12’ (3.6 m)
BLM6300
Single Phase
120 V/15 A outlet
NEMA 5-20R
12’ (3.6 m)
BLM550
Single Phase
220 V/20 A outlet
NEMA 6-20R
8’ (2.4 m)
BGB1208 Glue Binder
(Select only ONE outlet
configuration)
3 Phase
208-240 V/30 A outlet
NEMA L6-30R
3 Phase
208-240 V/30 A outlet
NEMA 14-30R
3 Phase
208-240 V/30 A outlet
NEMA L15-30R
7 Can only be attached to the Océ VarioPrint 6160 Ultra+, TP+, and MICR+ lines.
16 The Set Finisher is powered by the IIM 208V AC (on the Ultra+ machine only).
17 If the Print Guard units are installed, the customer must provide two, 115V AC, 20 amp, dedicated, single phase
lines. If a finisher is attached, the customer must supply a separate 208V AC, single phase, 20 amp line.
18 Two outlets are required for a system with one stacker, and three outlets are required for a system with two
stackers.
19 The BGB1208 Glue Binder can only be configured as a 220 V system.