Chapter 2
2-5
2.3.3 Laser Control
2.3.3.1 Auto Power Control (APC)
0019-9512
This is the control to emit a constant level of laser diode.
There are two types of APC; initial APC (note 1), and line space APC (note 2). The laser driver executes the same procedure for both controls. The following is the
details of the control procedure.
1) When the laser control signal enters LD1 forced ON mode (CNT0, CNT1, CNT2), the laser driver emits LD1 forcibly.
2) The emission level of LD1 is detected with photo diode (PD), converted from current output to voltage, and compared with the standard voltage (voltage equiv-
alent to the target laser level) with the comparator.
3) The laser driver controls the laser current to achieve the voltage of LD1 target level.
4) When the laser control signal enters LD forced OFF mode, the LD1 is forcibly turned off. The laser driver saves the adjusted laser intensity of the capacitor (C16).
5) When the adjustment of LD1 laser intensity is completed, the laser control signal enters LD2 forced ON mode; the laser driver emits LD2 forcibly.
The laser driver adjusts the LD2 laser intensity as in the case of LD1 and saves the adjusted laser intensity to the capacitor (C18).
2.3.4 Laser Scanner Motor Control
2.3.4.1 Overview
0019-9513
This is the control to rotate the scanner motor at a constant speed to emit the laser beam on the correct position on the photosensitive drum.
The following is the control circuit of the scanner motor.
F-2-4
The engine controller creates standard clock based on oscillation frequency of the oscillator (X300); the cycles of the standard clock is compared with that of BD
input signal (/BDI) with a frequency comparator and the rotations of the scanner motor is monitored.
The engine controller sends the scanner motor acceleration signal (ACC) and scanner motor deceleration signal (DEC) to the scanner motor driver according to the
detected rotation speed to control the rotation speed.
1. Initial APC
APC that is executed during initial rotation. APC adjusts laser intensity and detects faults in the laser.
2. Line space APC
APC that is executed during printing. Laser intensity for one line is adjusted before writing one line.
Engine controller
Motor driver PCB
BD PCB
Oscillator
Reference
clock
Frequency
comparator
Laser scanner unit
Integration
circuit
M
Scanner driver IC
Scanner motor
ACC
DEC
/BDI
Drive
circuit
CPU
ASIC
X300
+24VA
+24VA
Содержание LBP3250 Series
Страница 1: ...Aug 13 2008 Service Manual LBP3250 Series LBP3250 ...
Страница 9: ...Chapter 1 PRODUCT DESCRIPTION ...
Страница 17: ...Chapter 2 TECHNICAL REFERENCE ...
Страница 45: ...Chapter 3 DISASSEMBLY AND ASSEMBLY ...
Страница 66: ...Chapter 3 3 19 F 3 67 1 1 2 ...
Страница 67: ...Chapter 4 MAINTENANCE AND INSPECTION ...
Страница 71: ...Chapter 5 TROUBLESHOOTING ...
Страница 77: ...Chapter 6 APPENDIX ...
Страница 82: ...Aug 13 2008 PARTS CATALOG LBP3250 ...
Страница 88: ...2 2 FIGURE 100 EXTERNAL COVERS PANELS ETC 1 2 4 6 9 10 7 8 5 11 3 ...
Страница 90: ...2 4 FIGURE 101 INTERNAL COMPONENTS 1 SEE FIGURE 810 2 3 1 ...
Страница 92: ...2 6 FIGURE 102 INTERNAL COMPONENTS 2 2 5 3 1 4 ...
Страница 94: ...2 8 FIGURE 103 INTERNAL COMPONENTS 3 1 2 4 3 ...
Страница 96: ...2 10 FIGURE 810 FIXING PAPER DELIVERY ASS Y 1 2 3 3 ...
Страница 98: ......