© 2006 Buyers Laboratory Inc. WARNING: This material is copyrighted by Buyers Laboratory Inc. and is the sole property of Buyers Laboratory. Duplication of this proprietary report or excerpts from this report, in any man-
ner, whether printed or electronic (including, but not limited to, copying, faxing, scanning or use on a fax-back system), is illegal and strictly forbidden without written permission from Buyers Laboratory. Violators will be pros-
ecuted to the fullest extent of the law. To purchase reprints of any BLI reports or articles, contact BLI at (201) 488-0404. Buyers Laboratory Inc., 20 Railroad Avenue, Hackensack, NJ 07601. Contact us at [email protected].
LA
B
TE
ST
Canon imageRUNNER 3570
Buyers LaBoratory
Lab TesT RepoRT
© 2006 Buyers Laboratory Inc. WARNING: This material is copyrighted by Buyers Laboratory Inc. and is the sole property of Buyers Laboratory. Duplication of this proprietary report or excerpts from this report, in any man-
ner, whether printed or electronic (including, but not limited to, copying, faxing, scanning or use on a fax-back system), is illegal and strictly forbidden without written permission from Buyers Laboratory. Violators will be pros-
ecuted to the fullest extent of the law. To purchase reprints of any BLI reports or articles, contact BLI at (201) 488-0404. Buyers Laboratory Inc., 20 Railroad Avenue, Hackensack, NJ 07601. Contact us at [email protected].
LA
B
TE
ST
Canon imageRUNNER 3570
Buyers LaBoratory
Lab TesT RepoRT
PMs/Malfunctions
Service Required
Meter Count
(Impressions)
Impressions
Between Service
Meter count (beginning of test)
0
Image Quality
Performed routine
maintenance
160,000
End of test period
170,000
Total Misfeeds/Misfeed Rate
4/1 per 42,500
impressions
Service Calls
0
PMs
1
Total Service Calls (including PMs)
1
MULTITASKING EVALUATION
Secondary
Function
Primary
Function
SCAN
COPY
Yes
Yes
Yes
SCAN
Yes
Yes
Yes
COPY
Yes
Yes
Yes
NOTE: A “Yes” indicates that the user can initiate the secondary function while the primary function is taking place and
that no further user intervention will be required for the secondary function to take place.
In addition to a single-user multitasking test, which evaluates a unit’s ability to initiate or perform one function while
another function is already in progress (see chart above), BLI also tests a multifunctional product’s ability to handle
multiple jobs that would be likely to stack up in a multi-user networked environment.
RELIaBILIty
MULtItasKING
This report has been reproduced with the written permission of Buyers Laboratory Inc. Any duplication of this report, in whole or part, in any form or manner,
without the written permission of Buyers Laboratory, is unlawful and violators will be prosecuted. © 2006 Buyers Laboratory Inc. To purchase reprints,
contact BLI at (201) 488-0404 (x17) or at [email protected].